Trouble
Cause
Action
Correction
Contacts not
changing state at
the proper gate arm
angle.
Verify contact
programming setting.
Program each contact to the desired
degree it needs to change state
(*note the degree it changes state is
always with reference to the
horizontal
and not
the vertical gate
arm position).
Digital Contacts not
functioning as
intended
Verify the red Contact
LED's are not lit for the
corresponding contact in
question.
Verify contact programming setting
as stated above.
Check 20 amp
automotive fuse.
Replace fuse.
WARNING
NEVER REPLACE THE FUSE WITH A HIGHER AMPERE
RATING THAN THE CURRENT VALUE IDENTIFIED ON THE
FACE OF THE CONTROL BOARD.
MTSS features are
not functioning
properly
No gate indication
Verify the Red Gate
Position LED is not
illuminated.
Ensure the gate arm is within 5
degrees of the horizontal position.