PROGRAMMING
5-3
SIG-QG-21-01
NOVEMBER 2021
Version: A
SIEMENS S-80
ENTRANCE GATE
NEXT
SIEMENS S-80
PROGRAM
ENTER
PROGRAM GATE DESCENT
(12 SEC DEFAULT)
USE NEXT/PREVIOUS TO SELECT
VALUE FROM 10 TO 15 SEC
ENTER & NEXT
PROGRAM GATE ASCENT
(10 SEC DEFAULT)
USE NEXT/PREVIOUS TO SELECT
VALUE FROM 10 TO 12 SEC
ENTER
NEXT
PROGRAM CONTACT 1
OPEN/CLOSED FROM: XX
USE NEXT/PREVIOUS TO SELECT IF THE
CONTACT SHOULD BE OPEN OR CLOSED
IN HORIZONTAL POSITION
ENTER
USE NEXT/PREVIOUS TO SELECT THE
DEGREE THE CONTACT WILL CHANGE
STATE (BETWEEN 1 TO 88 DEGREES)
ENTER
REPEAT CONTACT
PROGRAMMING
STEPS FOR
REMAINING
CONTACTS (IF
USED)
GATE ARM LENGTH
(DEFAULT 16 FT)
ENTER
USE NEXT/PREVIOUS TO SELECT
VALUE FROM 12 TO 38 FEET
ENTER & NEXT
ARM RETENTION
ENTER
USE NEXT/PREVIOUS TO SELECT
ENABLED OR DISABLED
ENTER
NEXT
PROGRAM UP POSITION
(DEFAULT 88 DEGREES)
USE NEXT/PREVIOUS TO SELECT VERTICAL
POSITION FROM 70 TO 88 DEGREES
ENTER
ENTER
NEXT
PROGRAM
SET TO DEFAULT
CAUTION- ONLY
HIT ENTER IF YOU
WISH TO RESTORE
FACTORY DEFAULTS
NEXT
NO OF COMPLETE
CYCLES: 000000000
CAUTION- ONLY
HIT ENTER IF YOU
WISH TO RESET THE
CYCLE COUNTER
NEXT
DSIPLAY CONTRAST
(DEFAULT 30%)
ENTER
USE NEXT/PREVIOUS TO ADJUST
CONTRACST FROM 0 TO 100%
ENTER
END OF
PROGRAMMING
SEQUENCE
EXIT
NEXT
ENTER
ENTER
Figure 5-2 User Interface Menu System