SITRANS FUS080 transmitter
Operating Instructions, 07/2012, A5E03059912-02
83
Settings
B
B.1
Factory settings
The FUS080/SONOKIT is from factory configured according to the order specification.
For the calibration / configuration of the flowmeter the application specific pipe dimensions
and the specific transducer locations are used.
Table B- 1
Factory settings
Identification
1-path factory settings (DN
(100 to DN 1200)
2-path factory settings DN
(DN 200 to DN 1200)
Possible settings
Meter identification
-
-
Free text 15 characters
Application location
-
-
Free text 15 characters
Display menu
Menu 1- 5 (all)
Menu 1 – 5 (all)
Menu 1 – 5, min one of the
five
Pipe data
Number of paths
1
2
1 or 2
Inner pipe diameter (m)
See "Dimension dependent
settings"
See "Dimension dependent
settings"
Input to pipe geometry
program
Transducer distance (m)
See "Dimension dependent
settings"
See "Dimension dependent
settings"
Input to pipe geometry
program
Distance between sound
paths, path displacement (m)
See "Dimension dependent
settings"
See "Dimension dependent
settings"
Input to pipe geometry
program
Path angle (°)
See "Dimension dependent
settings"
See "Dimension dependent
settings"
Input to pipe geometry
program
Q max
See "Dimension dependent
settings"
See "Dimension dependent
settings"
Adjustable
Low flow cut-off (% of Qmax) 0.25 %
0.25 %
0 … 10%
Fliter time constant
5 s
5 s
5 … 1000 s
Geometry factor path 1
See "Dimension dependent
settings"
See "Dimension dependent
settings"
Auto set from pipe geometry
help program in PDM
Geometry factor path 2
-
See "Dimension dependent
settings"
Auto set from pipe geometry
help program in PDM
Correction factor
Costumer correction factor
1
1
0.5 … 1.5
Measuring unit and factors
Flow unit factor
3600
3600
Auto set from unit guide
Totalizer volume unit factor 1
1
Auto set from unit guide
Flow unit text
m
3
/h
m
3
/h
Auto set from unit guide, but
only m
3
/h can be shown on
display
Totalizer unit text
m
3
m
3
Auto set from unit guide, but
only m
3
can be shown on
display
Содержание SITRANS F US SONOKIT
Страница 2: ......
Страница 8: ...Table of contents SITRANS FUS080 transmitter 6 Operating Instructions 07 2012 A5E03059912 02 ...
Страница 16: ...Safety notes 2 4 Certificates SITRANS FUS080 transmitter 14 Operating Instructions 07 2012 A5E03059912 02 ...
Страница 46: ......
Страница 50: ...Functions 7 4 Hardware key SITRANS FUS080 transmitter 48 Operating Instructions 07 2012 A5E03059912 02 ...
Страница 70: ...Qualification certificate SITRANS FUS080 transmitter 68 Operating Instructions 07 2012 A5E03059912 02 ...