Connecting
5.2 Wiring the power supply and the output
SITRANS FUS080 transmitter
28
Operating Instructions, 07/2012, A5E03059912-02
5.2.2
Wiring the pulse output
CAUTION
Pulse output
The pulse output must be connected to equipment complying with Low Voltage Directive in
order to be considered safe. The isolation within the FUS080 pulse output is only a
functional isolation.
1.
Prepare cable ends as shown above.
2.
Connect output cables to terminals 56 and 57 (Output A) and to 66 and 67 (Output B)
according to use. The output functions are used as shown above.
3.
Ground cable shielding by fixing it with clamp.
CAUTION
EMC performance
Incorrect fixing of the cable shield will affect the EMC performance!
5.2.3
Mounting the transmitter
1.
Tighten power supply and pulse output cable glands.
2.
Mount transmitter.
Figure 5-5
Mounting the transmitter on terminal box