Parameter lists
A.4 Meter setup
SITRANS FUS080 transmitter
78
Operating Instructions, 07/2012, A5E03059912-02
A.4
Meter setup
Table A- 4
Meter setup parameters
Modbus
Address
Parameter
Default
value
Value
range
Access
level
Description
Meter Setup
40179
307
Flow velocity offset
0 m/s
-10 ... 10
m/s
HW key Velocity added to measured flow
velocity
40182
310
Calibration factor
1.0
0 ... 2
R/W
This calibration factor will be calculated
at the factory with wet-calibration.
For FUS080-SONOKIT (retrofit)
installations this parameter should be
calculated by the pipe geometric tool
(see 'Pipe geo. assistant' in 'Device'
menu)
40151
311
Adjustment Factor
1
- 2 ... 2
R/W
Meter correction factor for customer
adjustment of the calculated flow
value. Can be used at installations
where a reference meter is used to get
reference to the true flow rate
40196
312
Transducer cable
length
Product
dependent
0 ... 200
m
R/W
Cable length (m) from sensor to
transmitter
40173
372
Filter time constant
Product
dependent
0 ... 100 s R/W
General time filter for flow
measurement. Filter constant is the
time that must pass before the filter's
ouput value is at 70% of the change of
its input value. Higher number gives a
slower and more stable flow signal.
40184
380
Protect linearization
from user access.
No
No, Yes
Read
Protection of the linearization
parameters. It is decided by the order
number and cannot be changed.
The linearization parameters are listed
in the device menu 'Linearization'
Totalizer
40673
400
Flow direction totalizer
1
Forward
Forward,
Reverse,
Net
R/W
Calculation principle on flow direction
for forward, reverse or net flow
40675
401
Totalizer 1 change date Last
change
date
dd-mm-
yyyy;
hh:mm:ss
Read
Date and time when totalizer 1 function
was changed
40674
410
Flow direction totalizer
2
Reverse
Forward,
Reverse,
Net
R/W
Calculation principle on flow direction
for forward - reverse or net flow
40678
411
Totalizer 2 change date Last
change
date
dd-mm-
yyyy;
hh:mm:ss
Read
Date and time when totalizer 2 function
was changed
Содержание SITRANS F US SONOKIT
Страница 2: ......
Страница 8: ...Table of contents SITRANS FUS080 transmitter 6 Operating Instructions 07 2012 A5E03059912 02 ...
Страница 16: ...Safety notes 2 4 Certificates SITRANS FUS080 transmitter 14 Operating Instructions 07 2012 A5E03059912 02 ...
Страница 46: ......
Страница 50: ...Functions 7 4 Hardware key SITRANS FUS080 transmitter 48 Operating Instructions 07 2012 A5E03059912 02 ...
Страница 70: ...Qualification certificate SITRANS FUS080 transmitter 68 Operating Instructions 07 2012 A5E03059912 02 ...