Connecting
5.1 Wiring the transducer cables
SITRANS FUS080 transmitter
24
Operating Instructions, 07/2012, A5E03059912-02
Figure 5-2
Electrical connection to SONOKIT 2-path
Note
Ensure that the right cable entries are used.
1-path:
– Terminal 1A is connected to transducer 1A
– Terminal 1B is connected to transducer 1B
2-path:
As 1-path and additionally:
– Terminal 2A is connected to transducer 2A
– Terminal 2B is connected to transducer 2B
Note
For sensor (transducer) connection, see SONOKIT 1-path or SONOKIT 2-path Operating
Instructions.
3.
Remount connection board in wall/pipe mounting kit.