If extended diagnostic messages (Ext_Diag_Data) exist, this is displayed by the "Diag_Flag" of
the "Data_Exchange" service. If the master then calls the "Slave_Diag" service, the external
diagnostic data are supplied in the following form by the device:
Table B-8
Format of diagnostic data
Byte
No.
Profile designation
Value
Meaning
1
Header
8 (dec.)
(fixed) length of diagnostic data (number of bytes)
2
254 (dec.) (fixed)
3
1
(fixed)
4
0 or 1
Display of changes in diagnostic data (see below)
5
Diagnosis
Byte 1
(s. below)
Diagnostic information
6
Byte 2
--
(not supported)
7
Byte 3
--
(reserved)
8
Byte 4
(s. below)
Note on additional diagnostic data
The total length of the external diagnostic data is always 8 including the header.
The "Diag_Flag" is always set when something has changed in the last four bytes of the
diagnostic data (corresponds to the parameter "DIAGNOSIS") since the last message, i.e. even
when diagnostic messages disappear again so that the master can register every change in the
diagnostic data.
When a diagnostic message is active, the corresponding bit is set otherwise reset.
The following bits of the external diagnostic data are supported by SITRANS F M (all other bits
stay reset at all times):
Table B-9
Format of the diagnostic data, byte 4
Bit No.
Description
Meaning
0
Error appears
At least one bit of the following 4 bytes (DIAGNOSIS)
was set
1
Reset
At least one bit of the following 4 bytes (DIAGNOSIS)
was reset
2 ... 7
Reserved
---
The "Error appears" message has priority over the "Error disappears" message, i.e. if one
diagnostic bit is set and another reset simultaneously, "Error appears" is reported.
The DIAGNOSIS part contains diagnostic messages of the device and has the following structure
(Bit 0 = LSB, Bit 7 = MSB):
Table B-10
Format of the diagnostic data, Byte 5 (=DIAGNOSIS Byte 1)
Bit No.
Description
Meaning
Cause (local message)
0
DIA_HW_ELETR
Hardware failure of the elec‐
tronic
"Com.--Module failure"
Communications module cannot be addressed
Sensor failure (sensor failure)
"Measurement module failure"
4
DIA_MEM_CHKSUM
Memory error
Memory failure"
Profibus Communication
B.7 Diagnostics
TRANSMAG 2 with MAG 911/E
112
Operating Instructions, 03/2021, A5E00102775-AC
Содержание SITRANS F TRANSMAG 2
Страница 6: ...Table of contents TRANSMAG 2 with MAG 911 E 6 Operating Instructions 03 2021 A5E00102775 AC ...
Страница 10: ...Introduction 1 8 Notes on warranty TRANSMAG 2 with MAG 911 E 10 Operating Instructions 03 2021 A5E00102775 AC ...
Страница 52: ...Operating 7 2 SIMATIC PDM TRANSMAG 2 with MAG 911 E 52 Operating Instructions 03 2021 A5E00102775 AC ...
Страница 84: ...Troubleshooting 10 3 Error messages TRANSMAG 2 with MAG 911 E 84 Operating Instructions 03 2021 A5E00102775 AC ...
Страница 92: ...Dimension drawings TRANSMAG 2 with MAG 911 E 92 Operating Instructions 03 2021 A5E00102775 AC ...
Страница 104: ...Parameters TRANSMAG 2 with MAG 911 E 104 Operating Instructions 03 2021 A5E00102775 AC ...
Страница 126: ...Index TRANSMAG 2 with MAG 911 E 126 Operating Instructions 03 2021 A5E00102775 AC ...