3SU10 pushbuttons and indicator lights
5.1 3SU10 devices for use on 3-slot holder
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
97
Register ID key by number
The individual ID key can be read in, without it physically existing or being inserted in the
module, by entering the individual number in the PCT or by transferring it in the acyclic
dataset.
Application: After the system has been delivered, additional ID keys can be logged into the
system without them physically existing in the system.
Parameterizable selection mode
The selection mode can be parameterized for turning right and left. This allows the
authorization levels to be selected via both directions.
The function must be enabled in the PCT.
Application: If no direct deactivation is necessary, the authorization levels can be selected
more quickly and easily using this function.
Change to process image
The outputs or the selected authorization levels are listed in the process image via the cyclic
process data.
Application: Direct access on the bit level is possible, thus complex calculations are no
longer required.