12.2 Electronic modules for ID key-operated switches
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
325
12.2.5.6
“Individually codable ID keys only" parameter
“Individually codable ID keys only" parameter
1) “Individually codable ID keys only" disabled:
●
All authorization levels are activated.
2) “Individually codable ID keys only" enabled:
●
Only individually codable ID keys are permitted. In this case, only individually codable
ID keys are recognized, regardless of whether they are listed in the key list in the
electronic module or not. The ID groups 1 ... 4 are ignored.
Settings
Description
Default setting
0
Individually codable ID keys only: disabled
Disabled
1
Individually codable ID keys only: enabled
—
12.2.5.7
"Switch position delay" parameter
Switch position delay
The switch position delay specifies how long a temporary key position is displayed at the ID
key-operated switch (by green flashing of the LED on the electronic module for ID key-
operated switches). During this time, it is still possible to change the temporary key position
by turning the knob. The switch position delay restarts when turning of the rotary knob is
detected. During the switch position delay, the values at the outputs are not changed. When
the switch position delay has expired, the temporary key position is accepted as the current
key position. The status of the outputs is changed in accordance with this position.
Settings
Description
Default setting
1
Switch position delay: Minimum value
20 (2 seconds)
100
Switch position delay: Maximum value
—
Increment: 0.1 seconds