FNo.Abbreviation Meaning
OpFtEIOT
¨©©©©ª©©©©©©©©©©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©ª©©©
2083Emer.Flt L23EEmerg. O/C fault detection L23E
C
2084Emer.Flt L123Emerg. O/C fault detection L123
C
2085Emer.Flt 123EEmerg. O/C fault detection L123E
C
2091Emer. I>>
Emerg. O/C phase fault detection I>>
C OT
2093Emer. I>
Emerg. O/C phase fault detection I>
C OT
2097Emer. IE>
Emerg. O/C earth fault detection IE>
C OT
2121Emer. TI>>
Emerg. O/C prot.: Time TI>> expired
OT
2123Emer. TI>
Emerg. O/C prot.: Time TI> expired
OT
2127Emer. TIE>
Emerg. O/C prot.: Time TIE> expired
OT
2141Emer.Gen.TripEmerg. O/C protection: General Trip
OT
2142Emer.Trip1pL1Emerg. O/C protection: Trip 1pole L1
C OT
2143Emer.Trip1pL2Emerg. O/C protection: Trip 1pole L2
C OT
2144Emer.Trip1pL3Emerg. O/C protection: Trip 1pole L3
C OT
2145Emer.Trip 3p Emerg. O/C protection: Trip 3pole
C OT
2701>AR on
>AR: Switch on auto-reclose function
IOT
2702>AR off
>AR: Switch off auto-reclose function IOT
2703>AR block
>AR: Block auto-reclose function
CG IOT
2704>AR reset
>AR: Reset auto-reclose function
C IOT
2706>1p RAR block>AR: Block 1pole rapid auto-reclose
CG IOT
2707>3p RAR block>AR: Block 3pole rapid auto-reclose
CG IOT
2708>RAR block
>AR: Block rapid auto-reclose
CG IOT
2709>DAR block
>AR: Block delayed auto-reclose
CG IOT
2711>Start AR
>AR: External start for internal AR
C IOT
2712>Trip L1 AR >AR: Ext. Trip L1 for internal AR
C IOT
2713>Trip L2 AR >AR: Ext. Trip L2 for internal AR
C IOT
2714>Trip L3 AR >AR: Ext. Trip L3 for internal AR
C IOT
2715>Trip 1p AR >AR: Ext. 1pole trip for internal AR
C IOT
2716>Trip 3p AR >AR: Ext. 3pole trip for internal AR
C IOT
2721>DAR aft. RAR>AR: Delayed AR only after rapid AR
CG IOT
2730>CB ready
>AR: Circuit breaker ready for reclose IOT
2731>Sync.release>AR: Synchronism from ext. sync.-check IOT
2781AR off
AR: Auto-reclose is switched off
CG OT
2782AR on
AR: Auto-reclose is switched on
OT
2783AR inoperativAR: Auto-reclose is blocked
CG OT
2784AR not ready AR: Auto-reclose is not ready
OT
2785AR block.dyn.AR: Auto-reclose is dynamically blocked C OT
2787CB not ready AR: Circuit breaker not ready
OT
2788AR T-CB Exp. AR: CB supervision time expired
OT
2801AR in prog. AR: Auto-reclose in progress
C OT
2811RAR only
AR: Only rapid auto-reclosing allowed OT
2812RAR T-act.runAR: Action time for RAR is running
OT
2813RAR T-1p run.AR: 1pole dead time for RAR is running C OT
2814RAR T-3p run.AR: 3pole dead time for RAR is running C OT
2815RAR 1p Prog. AR: 1pole rapid auto-reclose program
OT
2816RAR 3p Prog. AR: 3pole rapid auto-reclose program
OT
2817RAR Zone Rel.AR: Zone extension for rapid reclosing OT
2818AR evolv.Flt.AR: Evolving fault recognition
OT
2831DAR Only
AR: Only delayed auto-reclosing allowed OT
2832DAR T-act.runAR: Action time for DAR is running
OT
2833DAR T-3p1 runAR: 3pole dead time 1 for DAR running C OT
2834DAR T-3p2 runAR: 3pole dead time 2 for DAR running C OT
2835DAR T-3p3 runAR: 3pole dead time 3 for DAR running C OT
2837DAR Zone Rel.AR: Zone extension for delayed reclose OT
2851AR Close Cmd.AR: Close command from auto-reclose
C C OT
2852RAR 1p Close AR: Close command after 1pole RAR cycle OT
2853RAR 3p Close AR: Close command after 3pole RAR cycle OT
2854DAR 3p Close AR: Close command after 3pole DAR cycle OT
2861AR T-Recl.runAR: Reclaim time is running
OT
¥©©©©¦©©©©©©©©©©©©©¦©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©¦©©¦©©¦©¦©©©¾