FNo.Abbreviation Meaning
OpFtEIOT
¨©©©©ª©©©©©©©©©©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©ª©©©
159LSA disruptedLSA (system interface) disrupted
CG
161I supervisionMeasured value supervision of currents O
162Failure ÉI
Failure: Current summation supervision CG OT
163Failure IsymmFailure: Current symmetry supervision CG OT
164U supervisionMeasured value supervision of voltages O
165Failure ÉUp-eFailure: Voltage sum superv. (ph-e)
CG OT
166Failure ÉUp-pFailure: Voltage sum superv. (ph-ph)
CG OT
167Failure UsymmFailure: Voltage symmetry supervision CG OT
168Failure UmeasFailure: Measuring voltages absent
CG OT
169Fuse-Failure Fuse failure monitor operated (>10s)
CG OT
170FFM pick-up Fuse failure monitor pick-up
CG
171Fail.PhaseSeqFailure: Phase sequence supervision
CG OT
203Flt.RecDatDelFault recording data deleted
C
204Flt.Rec.viaBIFault recording initiated via bin.inputC
205Flt.Rec.viaKBFault recording initiated via keyboard C
206Flt.Rec.viaPCFault recording initiated via PC interfC
244D Time=
Diff. time of clock synchronism
M
301Syst.Flt
Fault in the power system
CGC
302Fault
Flt. event w. consecutive no.
C
303E/F Det.
E/Flt.det. in isol/comp.netw.
CG E
354>CB Aux.3p cl>CB aux. contact:3poles closed (series) IOT
356>Manual Close>Manual close
IOT
357>CloseCmd.Blo>Block all close commands from externalCG IOT
361>VT mcb Trip >U Line side VT MCB tripped
CG IOT
362>V2 mcb Trip >U2 Busbar side VT MCB tripped
CG IOT
381>1p Trip Perm>External auto-reclose ready for 1pole CG IOT
382>Only 1pole >External AR programmed for 1pole only CG IOT
383>RAR Release >Release overreach zones RAR
CGCG IOT
384>DAR Release >Release overreach zones DAR
CGCG IOT
501Device FltDetGeneral fault detection of device
OT
502Dev. Drop-offGeneral drop-off of device
C
503Dev.FltDet L1General device fault detection: Ph. L1 OT
504Dev.FltDet L2General device fault detection: Ph. L2 OT
505Dev.FltDet L3General device fault detection: Ph. L3 OT
506Dev.FltDet N General device fault detection: Ph. N OT
511Device Trip General trip of device
G OT
512Dev.Trip 1pL1General 1pole trip of device: Phase L1 OT
513Dev.Trip 1pL2General 1pole trip of device: Phase L2 OT
514Dev.Trip 1pL3General 1pole trip of device: Phase L3 OT
515Dev.Trip 3p General 3pole trip of device
OT
516Dev.Trip forwGeneral trip for fault in forward dir. OT
517Dev.Trip rev.General trip for fault in reverse dir. C OT
521IL1/In=
Interrupted current: Phase L1(I/In)
C
522IL2/In=
Interrupted current: Phase L2(I/In)
C
523IL3/In=
Interrupted current: Phase L3(I/In)
C
545T-Drop
Time from fault detection to drop-off
546T-Trip
Time from fault detection to trip
561Manual Close Circuit breaker manually closed (pulse)C OT
562Man.Close CmdCB close command for manual closing
OT
563CB Alarm SuppCB alarm suppressed
OT
601IL1[%] =
Current in phase IL1 [%] =
M
602IL2[%] =
Current in phase IL2 [%] =
M
603IL3[%] =
Current in phase IL3 [%] =
M
621UL1E[%]=
UL1E [%]=
M
622UL2E[%]=
UL2E [%]=
M
623UL3E[%]=
UL3E [%]=
M
624UL12[%]=
UL12 [%] =
M
625UL23[%]=
UL23 [%] =
M
¥©©©©¦©©©©©©©©©©©©©¦©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©¦©©¦©©¦©¦©©©¾