Appendix
A.8 Information List
SIPROTEC, 7RW80, Manual
C53000-G1140-C233-1, Release date 10.2010
235
170.2092 25 fdiff too large (f2>f1) (25 f2>f1) SYNC function 1
OUT
On
Off
*
LED
BO
170.2093 25 fdiff too large (f2<f1) (25 f2<f1) SYNC function 1
OUT
On
Off
*
LED
BO
170.2094 25 alphadiff too large (a2>a1) (25
α
2>
α
1)
SYNC function 1
OUT
On
Off
*
LED
BO
170.2095 25 alphadiff too large (a2<a1) (25
α
2<
α
1)
SYNC function 1
OUT
On
Off
*
LED
BO
170.2096 25 Multiple selection of func-
groups (25 FG-Error)
SYNC function 1
OUT
On
Off
LED
BO
170.2097 25 Setting error (25 Set-Error)
SYNC function 1
OUT
On
Off
LED
BO
170.2101 Sync-group 1 is switched OFF
(25-1 OFF)
SYNC function 1
OUT
On
Off
*
LED
BO
41
36
1
Yes
170.2102 >BLOCK 25 CLOSE command
(>BLK 25 CLOSE)
SYNC function 1
SP
On
Off
*
LED BI
170.2103 25 CLOSE command is
BLOCKED (25 CLOSE BLK)
SYNC function 1
OUT
On
Off
*
LED
BO
41
37
1
Yes
171
Failure: Phase Sequence (Fail
Ph. Seq.)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
160
35
1
Yes
176
Failure: Phase Sequence Voltage
(Fail Ph. Seq. V)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
135
192
1
Yes
177
Failure: Battery empty (Fail Bat-
tery)
Device, General
OUT
On
Off
*
*
LED
BO
178
I/O-Board Error (I/O-Board error) Device, General
OUT
On
Off
*
*
LED
BO
181
Error: A/D converter (Error A/D-
conv.)
Device, General
OUT
On
Off
*
*
LED
BO
191
Error: Offset (Error Offset)
Device, General
OUT
On
Off
*
*
LED
BO
193
Alarm: NO calibration data avail-
able (Alarm NO calibr)
Device, General
OUT
On
Off
*
*
LED
BO
197
Measurement Supervision is
switched OFF (MeasSup OFF)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
135
197
1
Yes
203
Waveform data deleted (Wave.
deleted)
Osc. Fault Rec.
OUT_
Ev
on
*
LED
BO
135
203
1
No
234.2100 27, 59 blocked via operation (27,
59 blk)
27/59 O/U Volt.
IntSP
On
Off
*
*
LED
BO
235.2110
>BLOCK Function $00 (>BLOCK
$00)
Flx
SP
On
Off
On
Off
*
*
LED BI
FC
TN
BO
235.2111
>Function $00 instantaneous
TRIP (>$00 instant.)
Flx
SP
On
Off
On
Off
*
*
LED BI
FC
TN
BO
235.2112
>Function $00 Direct TRIP (>$00
Dir.TRIP)
Flx
SP
On
Off
On
Off
*
*
LED BI
FC
TN
BO
235.2113
>Function $00 BLOCK TRIP
Time Delay (>$00 BLK.TDly)
Flx
SP
On
Off
On
Off
*
*
LED BI
FC
TN
BO
235.2114
>Function $00 BLOCK TRIP
(>$00 BLK.TRIP)
Flx
SP
On
Off
On
Off
*
*
LED BI
FC
TN
BO
235.2115
>Function $00 BLOCK TRIP
Phase A (>$00 BL.TripA)
Flx
SP
On
Off
On
Off
*
*
LED BI
FC
TN
BO
235.2116
>Function $00 BLOCK TRIP
Phase B (>$00 BL.TripB)
Flx
SP
On
Off
On
Off
*
*
LED BI
FC
TN
BO
235.2117
>Function $00 BLOCK TRIP
Phase C (>$00 BL.TripC)
Flx
SP
On
Off
On
Off
*
*
LED BI
FC
TN
BO
235.2118
Function $00 is BLOCKED ($00
BLOCKED)
Flx
OUT
On
Off
On
Off
*
*
LED
BO
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on