Appendix
A.8 Information List
SIPROTEC, 7RW80, Manual
C53000-G1140-C233-1, Release date 10.2010
233
7
>Setting Group Select Bit 0 (>Set
Group Bit0)
Change Group
SP
*
*
*
LED BI
BO
135
51
1
Yes
8
>Setting Group Select Bit 1 (>Set
Group Bit1)
Change Group
SP
*
*
*
LED BI
BO
135
52
1
Yes
009.0100 Failure EN100 Modul (Failure
Modul)
EN100-Modul 1
IntSP
On
Off
*
*
LED
BO
009.0101 Failure EN100 Link Channel 1
(Ch1) (Fail Ch1)
EN100-Modul 1
IntSP
On
Off
*
*
LED
BO
009.0102 Failure EN100 Link Channel 2
(Ch2) (Fail Ch2)
EN100-Modul 1
IntSP
On
Off
*
*
LED
BO
15
>Test mode (>Test mode)
Device, General
SP
*
*
*
LED BI
BO
135
53
1
Yes
16
>Stop data transmission
(>DataStop)
Device, General
SP
*
*
*
LED BI
BO
135
54
1
Yes
51
Device is Operational and Pro-
tecting (Device OK)
Device, General
OUT
On
Off
*
*
LED
BO
135
81
1
Yes
52
At Least 1 Protection Funct. is
Active (ProtActive)
Device, General
IntSP
On
Off
*
*
LED
BO
160
18
1
Yes
55
Reset Device (Reset Device)
Device, General
OUT
on
*
*
160
4
1
No
56
Initial Start of Device (Initial Start) Device, General
OUT
on
*
*
LED
BO
160
5
1
No
67
Resume (Resume)
Device, General
OUT
on
*
*
LED
BO
68
Clock Synchronization Error
(Clock SyncError)
Device, General
OUT
On
Off
*
*
LED
BO
69
Daylight Saving Time (DayLight-
SavTime)
Device, General
OUT
On
Off
*
*
LED
BO
70
Setting calculation is running
(Settings Calc.)
Device, General
OUT
On
Off
*
*
LED
BO
160
22
1
Yes
71
Settings Check (Settings Check) Device, General
OUT
*
*
*
LED
BO
72
Level-2 change (Level-2 change) Device, General
OUT
On
Off
*
*
LED
BO
73
Local setting change (Local
change)
Device, General
OUT
*
*
*
110
Event lost (Event Lost)
Device, General
OUT_
Ev
on
*
LED
BO
135
130
1
No
113
Flag Lost (Flag Lost)
Device, General
OUT
on
*
m
LED
BO
135
136
1
Yes
125
Chatter ON (Chatter ON)
Device, General
OUT
On
Off
*
*
LED
BO
135
145
1
Yes
126
Protection ON/OFF (via system
port) (ProtON/OFF)
P.System Data 2
IntSP
On
Off
*
*
LED
BO
140
Error with a summary alarm
(Error Sum Alarm)
Device, General
OUT
On
Off
*
*
LED
BO
160
47
1
Yes
160
Alarm Summary Event (Alarm
Sum Event)
Device, General
OUT
On
Off
*
*
LED
BO
160
46
1
Yes
167
Failure: Voltage Balance (Fail V
balance)
Measurem.Superv
OUT
On
Off
*
*
LED
BO
135
186
1
Yes
170.0001 >25-group 1 activate (>25-1 act)
SYNC function 1
SP
On
Off
*
LED BI
170.0043 >25 Synchronization request
(>25 Sync requ.)
SYNC function 1
SP
On
Off
*
LED BI
170.0049 25 Sync. Release of CLOSE
Command (25 CloseRelease)
SYNC function 1
OUT
On
Off
*
LED
BO
41
201
1
Yes
170.0050 25 Synchronization Error (25
Sync. Error)
SYNC function 1
OUT
On
Off
*
LED
BO
41
202
1
Yes
170.0051 25-group 1 is BLOCKED (25-1
BLOCK)
SYNC function 1
OUT
On
Off
*
LED
BO
41
204
1
Yes
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on