Additional information
Additional information on how to commission an NX component is provided in:
● Commissioning Manual IBN CNC: NCK, PLC, Drive
See also
Connecting digital inputs/outputs (Page 80)
11.1.5
Technical Data
Table 11-9
Safety-related data
Protection class
III
Degree of protection to EN 60529
IPXXB
Approvals
CE, cULus
Pollution degree
2
Cooling
Open-circuit ventilation
Mounting position
Vertical
PE/ground connection
at the housing with M5 screw Torx / 3 Nm
Table 11-10 Electrical and mechanical data
Input voltage
24 V DC (20.4 – 28.8)
Current drain (without DRIVE-CLiQ and digital outputs) 0.3 A
Max. permitted output current
3.35 A
Power loss
15 W
Dimensions WxHxD (with spacers)
25 x 414 x 272 mm
Weight
2.58 kg
11.2
PP 72/48D PN
11.2.1
Description
Characteristics
I/O module PP 72/48D PN is a simple module (without a separate housing) for connecting
digital input/outputs as part of an automation system based on PROFINET IO.
Connectable components
11.2 PP 72/48D PN
NCU 1760
Equipment Manual, 02/2020, A5E45627861B AB
103
Содержание SINUMERIK ONE NCU 1760
Страница 8: ...Table of contents NCU 1760 8 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 36: ...Description 3 5 Dual fan module NCU 1760 36 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 44: ...Dimension drawings 5 1 NCU 1760 dimension drawing NCU 1760 44 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 48: ...Installation 6 4 Mounting the NCU without spacers NCU 1760 48 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 150: ...Connectable components 11 3 PP 72 48D PN 2 2A PN NCU 1760 150 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 154: ...Spare parts accessories 12 2 SD card NCU 1760 154 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 156: ...Safety symbols NCU 1760 156 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 160: ...Appendix A 2 Documentation overview SINUMERIK ONE NCU 1760 160 Equipment Manual 02 2020 A5E45627861B AB ...