11.2.3.3
X2 PROFINET
Data Transmission Rate and Cables
For PROFINET, you require a data transmission rate of 100 Mbit/s (Fast Ethernet). The
interfaces are designed for full-duplex mode; in other words, the ports can both transmit and
receive. For data transfer purposes you can use electrical twisted copper cables (twisted pair,
4-wire, 100Base-T):
● The transmission characteristics of these cables must meet the requirements of CAT5.
● The maximum length of the connections between the end device and network component
or between two network components (e.g. switch ports) must not exceed 100 m.
Pin assignment
Table 11-16 PROFINET interfaces X2, ports 1, 2
Pin
Signal name
Signal type
Meaning
1
TX+
O
Transmit data +
2
TX-
O
Transmit data -
3
RX+
I
Receive data +
4
N.C.
-
Reserved, do not use
5
N.C.
-
Reserved, do not use
6
RX-
I
Receive data -
7
N.C.
-
Reserved, do not use
8
N.C.
-
Reserved, do not use
Cable specification
Table 11-17 Cable specification at X2, ports 1, 2
Characteristic
Version
Connector type
RJ45 socket
Cable type
Industrial Ethernet cable (as of CAT5)
Max. cable length
100 m
LED displays
For diagnostic purposes, the RJ45 sockets are each equipped with a green and a yellow LED.
This allows the following information to be displayed for the respective PROFINET port:
Table 11-18 PROFINET ports LED displays
Name
Color
Status
Meaning
Link
Green
lit
Transfer rate 100 Mbit/s
off
No or faulty connection
Connectable components
11.2 PP 72/48D PN
NCU 1760
Equipment Manual, 02/2020, A5E45627861B AB
111
Содержание SINUMERIK ONE NCU 1760
Страница 8: ...Table of contents NCU 1760 8 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 36: ...Description 3 5 Dual fan module NCU 1760 36 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 44: ...Dimension drawings 5 1 NCU 1760 dimension drawing NCU 1760 44 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 48: ...Installation 6 4 Mounting the NCU without spacers NCU 1760 48 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 150: ...Connectable components 11 3 PP 72 48D PN 2 2A PN NCU 1760 150 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 154: ...Spare parts accessories 12 2 SD card NCU 1760 154 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 156: ...Safety symbols NCU 1760 156 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 160: ...Appendix A 2 Documentation overview SINUMERIK ONE NCU 1760 160 Equipment Manual 02 2020 A5E45627861B AB ...