![Siemens SINUMERIK ONE NCU 1760 Скачать руководство пользователя страница 149](http://html.mh-extra.com/html/siemens/sinumerik-one-ncu-1760/sinumerik-one-ncu-1760_equipment-manual_1266036149.webp)
Value
byte 1
Cause
Effect
Remedy
5
Internal error, system error
The "PNFault" LED is activated.
The outputs are switched off.
1)
The value 0x80 is stored in status byte 1.
The firmware has detected a system er‐
ror, this status can only be exited by
means of a switch-on / switch-off.
6
Range exceeded at the in‐
puts
Check input circuit and adjust, if required.
7
Range exceeded at the out‐
puts
Correct the values in the user program.
1)
The analog outputs retain their last specified value.
Diagnostics via status bytes 0/1
In status byte 0, the set operating modes are reflected e.g. "0x55" if control byte 0 = 0x55 has
been specified (voltage on all channels).
In the event of an error, the error bit is set in status byte 1 (bit 7). In the event of an error in one
channel, all channels are deactivated.
Table 11-66 Input image of analog inputs (excerpt)
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit3
Bit1
Bit0
m+0
0
0
0
0
0
0
0
0
m+1
Error bit
0
0
0
0
0
0
0
11.3.6
Technical data
Table 11-67 Technical data of the I/O module
Safety
Degree of protection
IP 00 according to EN 60529
Protection class
III; DVC A, (PELV) acc. to EN 61800-5-1
Approvals
cULus, CE
Electrical data
Rated voltage
24 V DC
Rated current
0.7 A
Power consumption at rated load
19 W (without digital outputs)
Power loss
18 W
Mechanical data
Dimensions WxHxD
150 x 300 x 35 mm
Weight, approx.
0.9 kg
For detailed technical data relating to the inputs and outputs, see the "Connecting" chapter.
X111, X222 and X333 digital inputs/outputs (Page 132)
Analog X3 inputs/outputs (Page 137)
Connectable components
11.3 PP 72/48D PN 2/2A PN
NCU 1760
Equipment Manual, 02/2020, A5E45627861B AB
149
Содержание SINUMERIK ONE NCU 1760
Страница 8: ...Table of contents NCU 1760 8 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 36: ...Description 3 5 Dual fan module NCU 1760 36 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 44: ...Dimension drawings 5 1 NCU 1760 dimension drawing NCU 1760 44 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 48: ...Installation 6 4 Mounting the NCU without spacers NCU 1760 48 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 150: ...Connectable components 11 3 PP 72 48D PN 2 2A PN NCU 1760 150 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 154: ...Spare parts accessories 12 2 SD card NCU 1760 154 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 156: ...Safety symbols NCU 1760 156 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 160: ...Appendix A 2 Documentation overview SINUMERIK ONE NCU 1760 160 Equipment Manual 02 2020 A5E45627861B AB ...