Bit
Signal name
Message
2
Diag_2
Overload DO byte 5/4
1
Diag_1
Overload DO byte 3/2
0
Diag_0
Overload DO byte 1/0
Note
The "alive and well" counter is a 3-bit modulo counter at the PP application level. The PP
application can be monitored using this counter. Failure of the application software does not
generally result in a communication failure, as this is developed in a hardware-supported
manner. The watch dog switches off the digital outputs, while the inputs remain at their last set
values.
Table 11-64 Overview of the messages in byte 1, depending on the "alive and well" counter
"alive and
well" counter
Value
byte 1
Message
0
0
Reserved
1
Temperature value
2
0
No error
1
Impermissible input voltage in the temperature measurement mode
2
Reserved
3
Overload at the outputs
4
Incorrect operating mode selection
5
Internal error, system error
6
Range exceeded at the inputs
7
Range exceeded at the outputs
3 ... 7
0
Reserved
Table 11-65 Elimination of error for "alive and well" counter status "2"
Value
byte 1
Cause
Effect
Remedy
1
In the temperature measure‐
ment operating mode, an in‐
put voltage is too high. The
hardware may become dam‐
aged/destroyed as a result.
The "PNFault" LED is activated.
The outputs are switched off.
1)
The value 0x80 is stored in status byte 1.
It is essential that a Pt100 element is
connected to terminals 3-4 or 7-8.
The module must be restarted with Pow‐
er ON after the error has been eliminated.
2
Reserved
-
-
3
Overload at the outputs
The "PNFault" LED is activated.
The outputs are switched off.
1)
The value 0x80 is stored in status byte 1.
Check the loads at the analog output.
The module must be restarted with Pow‐
er ON after the error has been eliminated.
4
Incorrect operating mode se‐
lection, e.g. temperature
measurement at the analog
outputs.
Selection of operating mode is rejected, If selected correctly, the module switches
to cyclic operation.
Connectable components
11.3 PP 72/48D PN 2/2A PN
NCU 1760
148
Equipment Manual, 02/2020, A5E45627861B AB
Содержание SINUMERIK ONE NCU 1760
Страница 8: ...Table of contents NCU 1760 8 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 36: ...Description 3 5 Dual fan module NCU 1760 36 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 44: ...Dimension drawings 5 1 NCU 1760 dimension drawing NCU 1760 44 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 48: ...Installation 6 4 Mounting the NCU without spacers NCU 1760 48 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 150: ...Connectable components 11 3 PP 72 48D PN 2 2A PN NCU 1760 150 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 154: ...Spare parts accessories 12 2 SD card NCU 1760 154 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 156: ...Safety symbols NCU 1760 156 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 160: ...Appendix A 2 Documentation overview SINUMERIK ONE NCU 1760 160 Equipment Manual 02 2020 A5E45627861B AB ...