3 Signal Overview
01.93
3.6 NC/PLC interface (DB 10...DB 25)
3.6
NC/PLC interface (DB 10...DB 25)
3.6.1
Channel-specific signals
Interface data blocks DB 10 to DB 25 are assigned to NC channels 1 to 16. The PLC that is to
process the NC must be specified in machine data MD 6000 - 6001 and MD 6100 - 6101, for
PLC I and PLC II respectively.
Note:
On GA2, software version 1 and higher, you can only select up to eight channels out of 16
because no more than two NC CPUs can be used.
Channel
DB
PLC MD for assignment to
PLC I
PLC II
1
2
3
4
DB 10
DB 11
DB 12
DB 13
6000.0
.1
.2
.3
6100.0
.1
.2
.3
5
6
7
8
DB 14
DB 15
DB 16
DB 17
.4
.5
.6
.7
.4
.5
.6
.7
9
10
11
12
DB 18
DB 19
DB 20
DB 21
6001.0
.1
.2
.3
6101.0
.1
.2
.3
13
14
15
16
DB 22
DB 23
DB 24
DB 25
.4
.5
.6
.7
.4
.5
.6
.7
3–14
© Siemens AG 1991 All Rights Reserved 6ZB5 410-0HE02
SINUMERIK 880 (PJ)