01.93
14 Command Channel (DB 41)
14.4.8 User data for "dynamic path dimension with exact stop" function
Data
Unit
Limits
Channel number
–
1...16
Axis number
–
1...24
Position
Units of input
resolution
Software limit
Software limit switch –
Feedrate (G94)
Feedrate (G95)
0.001 mm/min
0.0001 inch/min
0.001 mm/rev
0.0001 inch/rev
MD 280*:
Max. axial
speed
Preparatory
function
–
Bit 8:
0:
G90
1:
G91
Bit 9:
0:
G94
1:
G95
Bit 10:
1:
G68
0:
G01
K
v
factor
0.01/s
Max. input:
1000
Acceleration
10
4
units/s
2
(input resolution)
Max. input:
7FFF
H
Exact stop fine
Units (input
resolution)
10 ... 16 000
Note:
In the case of feedrate with G95 the THREAD CUTTING AND REVOLUTIONAL FEEDRATE
Option must be available.
© Siemens AG 1991 All Rights Reserved 6ZB5 410-0HE02
14–21