Installation
04/2005
SINAMICS G110 Operating Instructions
18
6SL3298-0AA11-0BP0
The serial numbers consist 13 characters and contains the date of manufacture,
e.g. XAP214-123456
XA
P214-123456 Characters 1-2 are the site where the product is built
XA
P
214-123456 Character 3 denotes the year e.g. R = 2003
XAP
2
14-123456 Character 4 is the month (1-9 =Jan-Sep, O =Oct, N =Nov, D =Dec)
XAP2
14
-123456 Characters 5-6 are the day of the month
XAP214
-
123456 Character 7 is a separator
XAP214-
123456
Characters 8-13 are the sequential serial number 1-999999
2.2 Power Losses
For information on the typical power losses for the SINAMICS G110 inverter,
please consult Table 7-6 on page 69.
2.3 Ambient operating conditions
Temperature
-10ºC to +50ºC (14ºF to 122ºF) see Table 7-8 on page 70 for derating information.
Humidity Range
≤
95% Non-condensing
Altitude
If the inverter is to be installed at an altitude greater than 1000m, derating will be
required. Figure 2-2 below shows the permissible rated input voltages and output
current for inverter installations from 1000 m to 4000 m above sea level.
Figure 2-2
Derating for Altitude
Shock and Vibration
Do not drop the inverter or expose to sudden shock. Do not install the inverter in an
area where it is likely to be exposed to constant vibration.
Mechanical strength to EN 60721-3-3
¾
Deflection:
0.075 mm (10 … 58 Hz)
¾
Acceleration:
10 m/s
2
(58 … 200 Hz)
Electromagnetic Radiation
Do not install the inverter near sources of electromagnetic radiation.
Содержание SINAMICS G110
Страница 1: ...Operating Instructions Edition 04 2005 sinamics SINAMICS G110 ...
Страница 10: ...Safety Instructions 04 2005 SINAMICS G110 Operating Instructions 10 6SL3298 0AA11 0BP0 ...
Страница 14: ...Overview 04 2005 SINAMICS G110 Operating Instructions 14 6SL3298 0AA11 0BP0 ...
Страница 72: ...Options 04 2005 SINAMICS G110 Operating Instructions 72 6SL3298 0AA11 0BP0 ...
Страница 78: ...Electro Magnetic Compatibility EMC 04 2005 SINAMICS G110 Operating Instructions 78 6SL3298 0AA11 0BP0 ...
Страница 86: ...List of Abbreviations 04 2005 SINAMICS G110 Operating Instructions 86 6SL3298 0AA11 0BP0 ...
Страница 90: ......