![Siemens SIMOTION TM15 Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/siemens/simotion-tm15/simotion-tm15_commissioning-manual_384566052.webp)
Error messages
TM15 / TM17 High Feature Operating Manual
52
Commissioning Manual, 05/2009
Errors cannot be acknowledged. The error message is automatically deleted as soon as the
device has been restarted or the cause of error has been corrected.
Note
The user program must always use a WORD variable to access the status word (individual
bits must be isolated by masking).
Diagnostic Interrupt
If the module error bit ERR is set, a diagnostic interrupt _SC_DIAGNOSTIC_INTERRUPT
(=201) is triggered with the following TaskStartInfo:
DINT
TSI#logBaseAdrIn
// valid only when not equal to
_SC_INVALID_ADDRESS
DINT
TSI#logBaseAdrOut
// valid only when not equal to
_SC_INVALID_ADDRESS
DINT
TSI#logDiagAdr
// valid only when not equal to
_SC_INVALID_ADDRESS
DWORD
TSI#details
// Supplementary information
UINT
TSI#eventClass
// 0x39 = fault has occurred
// 0x38 = fault has been corrected
UINT
TSI#faultId
// 0x42
TSI#details supplies the following supplementary information:
Bit
31-17
16
15-12
11-8
7-2
1
0
Function
0
0
0
1111
0
ERR
Fault
Bit 0 = 1
Module fault (set when ERR is set)
Bit 1 = 1
ERR (internal error)
Bit 11 to 8
Contains "digital I/O module" identifier
In addition to the diagnostic alarm, an entry is made in the diagnostic buffer if at least one of
the bits is set. "Module fault" is displayed.
For further information on the TaskStartInfo, refer to the "SIMOTION ST Structured Text"
Manual.
Содержание SIMOTION TM15
Страница 6: ......
Страница 44: ......
Страница 50: ......
Страница 68: ......
Страница 84: ......
Страница 88: ......
Страница 90: ......
Страница 94: ......
Страница 98: ...SIMOTION SIMOTION SCOUT TM15 TM17 High Feature Operating Manual Commissioning Manual 05 2009 98 ...
Страница 99: ...SIMOTION SIMOTION SCOUT TM15 TM17 High Feature Operating Manual Commissioning Manual 05 2009 99 ...