![Siemens SIMOTION P320-4 E Скачать руководство пользователя страница 126](http://html.mh-extra.com/html/siemens/simotion-p320-4-e/simotion-p320-4-e_manual_380823126.webp)
FAQs / error correction
Possible cause
Possible remedy
Error message on the
screen:
Operating system not found
● No operating system
present.
● Incorrect active boot
partition.
● Incorrect drive entries in
the SETUP.
Check whether one of the specified causes is present:
Wrong time and/or date on
the PC.
-
● Press <ESC> during the boot sequence to open BIOS Setup.
Detailed information on the BIOS setup can be found in the
section Starting Bios settings Hotplug Enabled - BIOS
Setup (Page 127).
● Set the time and date in the setup menu.
Although the BIOS setting is
OK, the time and date are
still wrong.
The backup battery is emp‐
ty.
Replace the backup battery.
See SIMOTION P320-4 E / P320-4 S Commissioning and
Hardware Installation Manual > Service and maintenances >
Replacing the backup battery.
If the problem cannot be resolved by replacing the battery, then
contact your technical support team.
UPS does not function.
The operating system does
not have a suitable driver for
the UPS.
Install a suitable driver; the correct driver can often be downloa‐
ded from the homepage of the device's manufacturer.
Note the SIMOTION P320-4 E / P320-4 S Commissioning and
Hardware Installation Manual > Power on and software installa‐
tion > Customer-specific software.
The display in the BIOS for
the PROFINET MAC ad‐
dress is incorrect
(00:00:00:00:00:00).
-
The correct MAC addresses can be taken from the rating plate
on the housing.
See also Device identification data (Page 79), Section MAC ad‐
dresses.
Troubleshooting/FAQs
8.1 Error correction
SIMOTION P320-4 E / P320-4 S
126
Manual, 03/2018, A5E36004933B
Содержание SIMOTION P320-4 E
Страница 10: ...Table of contents SIMOTION P320 4 E P320 4 S 10 Manual 03 2018 A5E36004933B ...
Страница 48: ...Industrial security 2 4 Product specific measures SIMOTION P320 4 E P320 4 S 48 Manual 03 2018 A5E36004933B ...
Страница 76: ...Description 3 3 HMI and SIMOTION SCOUT SIMOTION P320 4 E P320 4 S 76 Manual 03 2018 A5E36004933B ...
Страница 132: ...Troubleshooting FAQs 8 2 Hotplug Enabled BIOS settings SIMOTION P320 4 E P320 4 S 132 Manual 03 2018 A5E36004933B ...
Страница 154: ...Spare parts 11 1 Available spare parts for SIMOTION P320 4 SIMOTION P320 4 E P320 4 S 154 Manual 03 2018 A5E36004933B ...
Страница 156: ...Standards and approvals A 1 General rules SIMOTION P320 4 E P320 4 S 156 Manual 03 2018 A5E36004933B ...
Страница 166: ...Index SIMOTION P320 4 E P320 4 S 166 Manual 03 2018 A5E36004933B ...