Application planning
4.5 Selecting and manufacturing the mounting cut-out
SIMOTION P350-3 and Panels
82
Manual, 05/2009
Figure 4-3
Component label
The component label has the order number 6AU… of the general device and its serial
number S T-xxxxxxxxx.
Further information is available at the product support link in the Preface.
See also
4.5
Selecting and manufacturing the mounting cut-out
Requirement
The degree of protection suitable to the field of application and thereby the method of
attachment have been selected.
Procedure
1.
Follow the installation instructions.
2.
Select a location suitable for installation, taking into account the installation instructions
and the chosen installation position.
3.
On the basis of the dimension diagrams, check whether the required screw and pressure
points on the rear and the hatched seal area are easily accessible after the completion of
the mounting cut-out. Otherwise the mounting cut-out is useless.
4.
Complete the mounting cut-out in accordance with the dimensions.
See also
Mounting dimensions for SIMOTION P012K (Page 118)
Mounting dimensions for SIMOTION P012T (Page 118)
Mounting dimensions for SIMOTION P015T (Page 119)