Technical specifications
B
Technical specifications of the sensor box
Dimensions W × H × D (mm)
380 × 380 × 210
Power supply
110/230 V AC
Certification
CE, UL
Degree of protection:
IP 66
Corrosion protection
C2, C3, C4 according to EN ISO 12944-5:2018 when the box is
closed
Electromagnetic compatibility
EMC protection requirements according to the EMC Directive
2014/30/EU
Area of application
High-voltage motors connected directly to the line supply
(purely DOL operation - and not controlled by a converter or
inverter).
WEEE
Category 5, small devices B2B (business to business)
Environmental conditions
Climatic conditions for operating the sensor box
Minimum air pressure
795 hPa
Maximum air pressure
1080 hPa
Ambient temperature
-20 °C to +40 °C
B.1
Terminal diagram for the sensor box
The following diagram shows the terminal diagram of the sensor box for the CE version:
Speedsensor
Temperatursensors
=
2
0
+
P
0
0
1
-X
2
99
1
0
1
0
1
1
1
1
S
ig
n
a
l
P
lu
s
2
4
V
M
-G
ro
u
n
d
rpm
Sensor
=
2
0
+
P
0
0
1
-X
2
1
3
1
3
1
4
1
4
N
D
E
-R
1
N
D
E
-R
2
N
D
E
B
e
a
ri
n
g
s
w
b
r
b
l
rd
w
t
1
5
1
5
1
6
1
6
D
E
-R
1
D
E
-R
2
D
E
B
e
a
ri
n
g
rd
w
t
1
7
1
7
1
8
1
8
1
R
1
1
R
2
W
IN
D
IN
G
1
rd
w
t
1
9
1
9
2
0
2
0
2
R
1
2
R
2
W
IN
D
IN
G
2
rd
w
t
1
2
1
2
n
.c
.
w
t
2
1
2
1
2
2
2
2
3
R
1
3
R
2
W
IN
D
IN
G
3
rd
w
t
2
3
2
3
2
4
2
4
4
R
1
4
R
2
W
IN
D
IN
G
4
O
R
S
P
A
R
E
rd
w
t
2
5
2
5
2
6
2
6
5
R
1
5
R
2
W
IN
D
IN
G
5
O
R
S
P
A
R
E
rd
w
t
2
7
2
7
2
8
2
8
6
R
1
6
R
2
W
IN
D
IN
G
6
O
R
S
P
A
R
E
rd
w
t
DI
2
9
2
9
3
0
3
0
+
2
4
V
S
ig
n
a
l
D
ig
.
In
p
u
t
M
o
to
r
O
K
+
2
4
V
S
ig
n
a
l
D
ig
.
In
p
u
t
M
o
to
r
O
K
Power supply
Vibration sensors
=
1
0
+
P
0
0
1
-X
1
11
22
P
E
P
E
L
1
N
P
E
AC
110V or 230V
supply
=
2
0
+
P
0
0
1
-X
2
11
22
A
B
N
D
E
R
A
D
IA
L
4
5
°
b
r
b
l
g
n
ye
rd
b
k
33
44
A
B
N
D
E
R
A
D
IA
L
3
1
5
°
O
R
D
E
A
X
IA
L
rd
b
k
55
66
A
B
D
E
R
A
D
IA
L
4
5
°
rd
b
k
77
88
A
B
D
E
R
A
D
IA
L
3
1
5
°
O
R
S
P
A
R
E
rd
b
k
Ethernet
=
3
0
+
P
0
0
1
-A
2
2
P
2
P
2
E
th
e
rn
e
t
Figure B-1
Terminal diagram (CE version)
The following diagram shows the terminal diagram of the sensor box for the UL version:
Operating Instructions, 06/2020
71
Содержание SIMOTICS CONNECT 600
Страница 2: ......
Страница 8: ...Introduction 1 2 Naming convention 6 Operating Instructions 06 2020 ...
Страница 14: ...Safety instructions 2 6 Security recommendations 12 Operating Instructions 06 2020 ...
Страница 34: ...Connection 6 3 Connecting the IPC 32 Operating Instructions 06 2020 ...
Страница 42: ...Operation 8 1 Data evaluation with SIDRIVE IQ 40 Operating Instructions 06 2020 ...
Страница 62: ...Maintenance 9 11 Deleting the data of the connectivity module 60 Operating Instructions 06 2020 ...
Страница 66: ...Replacement parts 10 2 Replacement parts for the connectivity module 64 Operating Instructions 06 2020 ...
Страница 70: ...Disposal 11 4 Information according to Article 33 of the REACH regulation 68 Operating Instructions 06 2020 ...
Страница 72: ...Service support A 1 Product support 70 Operating Instructions 06 2020 ...
Страница 76: ...Known problems C 1 Known problems of the current software version 74 Operating Instructions 06 2020 ...
Страница 79: ......