Installing the Device
2.7.2 Connecting DC Power
1. Connect the positive wire from the power source to the positive terminal on the
terminal block.
1
2
3
1
Live Terminal
2
Ground Terminal
3
Neutral Terminal
Figure 2.7
DC Terminal Block Wiring
2. Connect the negative wire from the power source to the neutral terminal on the
terminal block.
IMPORTANT
If the ground terminals are not connected to safety Earth, the chassis ground
connection must be connected. For more information, refer to
3. Using a braided wire or other appropriate grounding wire, connect the ground
terminal to the chassis ground connection. The ground terminal is used as the
ground conductor for all surge and transient suppression circuitry internal to the
unit.
4. Connect the ground terminal on the power source to the ground terminal on the
device. For more information, refer to
"Grounding the Device (Page 14)"
.
18
RUGGEDCOM RX5000
Installation Manual, 01/2021, C79000-G8976-1058-13