background image

SIMATIC NET

Rugged Multi Service Platforms

RUGGEDCOM RX5000

Installation Manual

Preface

Introduction

1

Installing the Device

2

Device Management

3

Modules

4

Technical Specifications

5

Certification

6

01/2021

C79000-G8976-1058-13

Содержание SIMATIC NET RUGGEDCOM RX5000

Страница 1: ...Edition 01 2021 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX5000 https www siemens com ...

Страница 2: ...ugged Multi Service Platforms RUGGEDCOM RX5000 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Modules 4 Technical Specifications 5 Certification 6 01 2021 C79000 G8976 1058 13 ...

Страница 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 4: ...pported Fiber Optic Cables 5 2 Installing the Device 7 2 1 General Procedure 8 2 2 Unpacking the Device 8 2 3 Mounting the Device 8 2 3 1 Mounting the Device to a Rack 9 2 3 2 Mounting the Device to a Panel 11 2 4 Installing the Chassis Ground Connection 13 2 5 Grounding the Device 14 2 6 Connecting the Failsafe Alarm Relay 14 2 7 Connecting Power 15 2 7 1 Connecting AC Power 16 2 7 2 Connecting D...

Страница 5: ...tions 33 5 3 Operating Environment 33 5 4 Mechanical Specifications 34 5 5 Dimension Drawings 34 6 Certification 37 6 1 Approvals 37 6 1 1 TÜV SÜD 37 6 1 2 European Commission EC 37 6 1 3 FDA CDRH 38 6 1 4 FCC 38 6 1 5 ISED 38 6 1 6 ISO 39 6 1 7 ACMA 39 6 1 8 RoHS 39 6 1 9 Other Approvals 40 6 2 EMC and Environmental Type Tests 40 iv RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 1...

Страница 6: ...odules Catalog for RX5000 https support industry siemens com cs ww en view 109748779 RUGGEDCOM SFP Transceivers Catalog https support industry siemens com cs ww en view 109482309 Accessing Documentation The latest user documentation for RUGGEDCOM RX5000 is available online at https support industry siemens com To request or inquire about a user document contact Siemens Customer Support Registered ...

Страница 7: ...s customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure us...

Страница 8: ...ncluding FAQs and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 ...

Страница 10: ...ol applications The RUGGEDCOM RX5000 is a scalable modular platform providing the ability to change the configuration as the network grows and needs change This section provides more information about the RUGGEDCOM RX5000 1 1 Feature Highlights Ethernet Ports Up to 96 x 10 100Base TX copper Ethernet ports 2 x 10 100 1000Base TX copper Ethernet ports Up to 48 x 100Base FX fiber optical Ethernet por...

Страница 11: ...2 1 Control Module 2 Power Supply Module 3 Line Module Typical 4 Alarm Indicator LED 5 Lamp Test Alarm Cut Off LT ACO Button 6 Management Ethernet Port 7 Utility USB Port 8 RS232 Serial Console Port DB9 9 Failsafe Alarm Relay 10 CompactFlash Card Port 11 Power Supply Module Indicator LEDs 12 Power Supply Terminal Block Figure 1 1 RUGGEDCOM RX5000 Modules When the RUGGEDCOM RX5000 is configured for...

Страница 12: ...ic Utility USB Port Use the USB port to upgrade the RUGGEDCOM RUGGEDCOM RX5000 software or install files such as configuration files and feature key files For more information refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX5000 Compact Flash Card Port Houses the CompactFlash CF card that contains active and backup installations of RUGGEDCOM RUGGEDCOM RX5000 along with the conf...

Страница 13: ...nment Decommissioning This device may include sensitive proprietary data Before taking the device out of service either permanently or for maintenance by a third party make sure it has been fully decommissioned For more information refer to the associated Configuration Manual Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a...

Страница 14: ...munication new and pre existing communication paths should be verified for TIA EIA 568 A compliance The following table summarizes the relevant cabling standards Cabling Category 1000Base TX Compliant Required Action 5 No New wiring infrastructure required 5 Yes Verify TIA EIA 568 A compliance 5e Yes No action required New installations should be designed with Category 5e or higher 6 Yes No action...

Страница 15: ...th MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized 6 RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 ...

Страница 16: ...NG Radiation hazard risk of serious personal injury This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties nu...

Страница 17: ...t the failsafe alarm relay 5 Connect power to the device and ground the device to safety Earth 6 Connect the device to the network 7 Configure the device 2 2 Unpacking the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included IMPORTANT If any item is mi...

Страница 18: ...ace Note For detailed dimensions of the device with mounting hardware installed refer to Dimension Drawings Page 34 2 3 1 Mounting the Device to a Rack For installations the RUGGEDCOM RX5000 can be equipped with adapters pre installed at the front or rear of the chassis Additional adapters are provided to further secure the device in high vibration or seismically active locations RUGGEDCOM RX5000 ...

Страница 19: ... rear of the chassis To make the management ports and LEDs accessible install the adapters at the front of the chassis Note The chassis features multiple mounting holes allowing the adapters to be installed up to 25 mm 1 in from the face of the device 1 2 3 1 2 3 1 Rear 2 Front 3 Adapter Figure 2 1 Adapters 2 If required install adapters on the opposite side of the device to protect from vibration...

Страница 20: ...equired However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space 4 Secure the adapters to the rack using the supplied hardware 2 3 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RX5000 can be equipped with adapters pre installed on each side of the chassis The adapters ...

Страница 21: ... the Device to a Panel To mount the device to a panel do the following 1 Place the device against the panel and align the adapters with the mounting holes 1 2 2 1 Screw 12 RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 ...

Страница 22: ...d to safety Earth a connection must be provided from the chassis ground terminal on the RUGGEDCOM MX5000 chassis IMPORTANT If the ground terminal on the power supply module s is connected to safety Earth a connection from the chassis ground terminal is not required 1 Position the grounding cable and external tooth lock washer on the RUGGEDCOM MX5000 3 2 1 1 External Tooth Lock Washer 2 8 32 5 16 P...

Страница 23: ...nd terminal on the power supply module s is connected to safety Earth a connection from the chassis ground terminal is not required The RUGGEDCOM RX5000 chassis ground terminal uses a 8 32 screw It is recommended to terminate the ground connection with a 8 ring lug and torque it to 3 4 N m 30 lbf in 2 1 1 8 32 Screw 2 8 Ring Lug Figure 2 4 Chassis Ground Connection 2 6 Connecting the Failsafe Alar...

Страница 24: ...ecure reliable connections under severe shock or vibration For information about installing or removing a power module refer to Installing Removing Power Supply Modules Page 30 DANGER Electrocution hazard risk of serious personal injury or death The device may have two power modules equipped which may be connected to separate power sources Make sure all power sources are off before servicing the p...

Страница 25: ...do the following DANGER Electrocution hazard risk of death serious personal injury and or damage to the device Make sure the supplied cover is always installed over high voltage screw type terminal blocks NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a DC power supply terminal block Damage to the power supply may occur Note The terminal block is installed u...

Страница 26: ...r appropriate grounding wire connect the ground terminal to the chassis ground connection The ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Connect the ground terminal on the power source to the ground terminal on the device For more information refer to Grounding the Device Page 14 2 7 2 Connecting DC Power To connect DC p...

Страница 27: ...cted to safety Earth the chassis ground connection must be connected For more information refer to Grounding the Device Page 14 3 Using a braided wire or other appropriate grounding wire connect the ground terminal to the chassis ground connection The ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Connect the ground terminal...

Страница 28: ...ntrol and RUGGEDCOM RX5000 interfaces The serial console port provides access to RUGGEDCOM RX5000 s console interface while the management port provides access to RUGGEDCOM RX5000 s console and Web interfaces The serial console port implements RS232 DCE Data Communication Equipment on a DB9 connector The following is the pin out for the port 1 1 5 6 9 Figure 3 1 Serial DB9 Console Port Pin Name De...

Страница 29: ... Note Single mode fiber ports only support Ultra Physical Contact UPC cable connectors 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM RX5000 interface For more information about configuring the device refer to the RUGGEDCOM ROX Configuration Manual associated with the installed softwa...

Страница 30: ... by Siemens for use with this device Removing the CF card in any scenario other than those described in this section Inserting the CF card To insert the CF card into the device do the following IMPORTANT The device should only be powered on when the CF card is present 1 Make sure the device is powered down 2 Remove the CF card access panel 3 Insert the CF card into the slot until it is fully seate...

Страница 31: ... device is powered down 2 Remove the CF card access panel 3 2 1 1 Ejector Button 2 CompactFlash Card 3 Access Panel Figure 3 4 Removing the CF Card 3 Press the ejector button to the left of the CF card and then pull the card out 4 Secure the CF card access panel to the chassis 22 RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 ...

Страница 32: ...eld replaceable Use the RUGGEDCOM RX5000 software to determine which ports are equipped on the device For more information refer to the RUGGEDCOM ROX Configuration Manual for the device Note Switch modules are only compatible with 8 port fiber optic Ethernet modules 2 3 4 6 7 8 9 1 5 10 1 Power Supply Module PS1 2 Ethernet Module Slot LM1 3 Ethernet Module Slot LM2 4 Ethernet Module Slot LM3 5 Con...

Страница 33: ...s Interface TX Port Type RJ45 Distance 100 m 328 ft Article Numbers 6GK6050 0AL20 0NB0 Standard 6GK6050 0AL20 0NB1 Conformal Coated RUGGEDCOM RX5000PN LM 4CG01 Specifications Ports 4 Speed 1000 Mbps Interface TX Port Type RJ45 Distance 100 m 328 ft Article Numbers 6GK6050 0AL20 0FC0 Standard 6GK6050 0AL20 0FC1 Conformal Coated Fiber Optic Ethernet Modules RUGGEDCOM RX5000PN LM 8FX01 Specifications...

Страница 34: ...umbers 6GK6050 0AL20 0KB0 Standard 6GK6050 0AL20 0KB1 Conformal Coated Control Modules RUGGEDCOM RX5000PN CM01 L2SE Specifications Layer 2 Standard Edition Article Numbers 6GK6050 0AL30 0AA0 6GK6050 0AL30 0AA1 RUGGEDCOM RX5000PN CM01 L3SEL3HW Specifications Layer 3 Standard Edition Layer 3 hardware Article Numbers 6GK6050 0AL30 0BA0 6GK6050 0AL30 0BA1 RUGGEDCOM RX5000PN CM01 L3SECL3HW Specificatio...

Страница 35: ...ticle Numbers 6GK6050 0AL40 0JA0 Standard 6GK6050 0AL40 0JA1 Conformal Coated RUGGEDCOM RX5000PN SM32 Specifications Ports 2 Speed 1000 Mbps Interface TX Port Type RJ45 Distance 100 m 328 1 ft Article Numbers 6GK6050 0AL40 0MA0 Standard 6GK6050 0AL40 0MA1 Conformal Coated RUGGEDCOM RX5000PN SM34 Specifications Mode MM Speed 1000 Mbps Interface SX Wavelength 850 nm Ports 2 Port Type LC Distance 500...

Страница 36: ...formal Coated Blank Modules RUGGEDCOM RX5000PN PS XX Specifications Article Numbers 6GK6050 0AL10 0AA0 RUGGEDCOM RX5000PN LM Blank Specifications Article Numbers 6GK6050 0AL20 0AA0 4 2 Installing Removing Line Modules Upon installing a new line module in the device all features associated with the module are available in RUGGEDCOM RX5000 For more information refer to the RUGGEDCOM ROX Configuratio...

Страница 37: ...lure Always make sure slots are not left empty and open ports are protected with plugs or covers Note Control and switch modules are not hot swappable Power to the device must be disconnected before removing these modules Removing a Line Module To remove a line module do the following 1 For Control and switch modules only make sure power to the device has been disconnected and wait approximately t...

Страница 38: ...the rack 7 For control and switch modules only connect power to the device Installing a Line Module To install a line module do the following 1 For Control and switch modules only make sure power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate 2 Optional If the device is installed in a rack remove it from the rack 3 Remove the current mo...

Страница 39: ...ecure the module 6 Optional If necessary install the device in the rack 7 For control and switch modules only connect power to the device 4 3 Installing Removing Power Supply Modules The RUGGEDCOM RX5000 supports dual redundant power supplies that can be installed in any combination 1 2 1 Power Supply Module PS1 30 RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 ...

Страница 40: ... is not necessary to turn off power to the device Removing a Power Supply Module To remove a power module do the following 1 Loosen the screws that secure the module to the chassis until the module can be removed 3 2 1 1 Screws 2 Power Supply 3 Chassis Figure 4 6 Removing a Power Supply 2 Slide the module out of the chassis 3 Install a new or blank module to prevent the ingress of dust and dirt In...

Страница 41: ...Module 3 Hand tighten the screws to secure the power module to the chassis 4 Turn on power to the device and confirm the module is receiving and supplying power This is indicated by the LEDs on the module LED State Description O Green The module is supplying power I Green The module is receiving power 32 RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 ...

Страница 42: ...y fuse Internal fuse is not user replaceable d Rating at 85 C 185 F ambient temperature at worst case load 5 2 Failsafe Relay Specifications Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 2 A 60 W 125 VDC 0 24 A 30 W 125 VAC 0 5 A 62 5 W 220 VDC 0 24 A 60 W 250 VAC 0 25 A 62 5 W 1500 Vrms for 1 minute 5 3 Operating Environment The RUGGEDCOM RX5000 is rated to operate under the ...

Страница 43: ...he RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non condensing 5 4 Mechanical Specifications Weight 14 16 kg 30 35 lbs Ingress Protection IP40 Chassis Material Aluminum 5 5 Dimension Drawings Note All dimensions are in millimeters unless otherwise stated 34 RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 ...

Страница 44: ...ns 5 5 Dimension Drawings 441 7 446 8 469 6 479 8 221 5 311 9 5 8 16 0 31 8 10 9 25 4 177 8 175 3 16 0 12 7 101 6 117 6 133 4 Figure 5 1 Overall Dimensions RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 35 ...

Страница 45: ...Technical Specifications 5 5 Dimension Drawings 36 RUGGEDCOM RX5000 Installation Manual 01 2021 C79000 G8976 1058 13 ...

Страница 46: ...ith UL 62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements 6 1 2 European Commission EC This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EC directives EN 62368 1 Information Technology Equipment Safety Part 1 General Requirements EN 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Gener...

Страница 47: ...mply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interfe...

Страница 48: ...ction 182 of the Radiocommunications Act 1992 Telecommunications Labelling Customer Equipment and Customer Cabling Notice 2001 made under Section 407 of the Telecommunication Act 1997 The device is marked with an RCM symbol to indicate compliance when sold in the Australian region A copy of the Declaration of Conformity is available via Siemens Industry Online Support at https support industry sie...

Страница 49: ...ion Test Levels Severity Levels Enclosure Contact 8 kV 4 IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure Ports 20 V m Note a Signal ports 4 kV 2 5 kHz Note a DC Power ports 4 kV 4 AC Power ports 4 kV 4 IEC 61000 4 4 Burst Fast Transient Earth ground ports 4 kV 4 Signal ports 4 kV line to earth 2 kV line to line 4 DC Power ports 2 kV line to earth 1 kV line to line 3 IE...

Страница 50: ...rts 2 kV Fail Safe Relay output DC Power ports 2 kV Dielectric Strength AC Power ports 2 kV Signal ports 5 kV Fail Safe Relay output DC Power ports 5 kV IEC 60255 5 HV Impulse AC Power ports 5 kV a Siemens specified severity levels IEEE 1613 EMC Type Tests Note The RUGGEDCOM RX5000 meets Class 2 requirements for an all fiber configuration and Class 1 requirements for copper ports Description Test ...

Страница 51: ...Strength AC Power ports 2 kV Environmental Type Tests Test Description Test Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 cycles IEC 60255 21 1 Vibration 2 g 10 150 Hz IEC 60255 21 2 Shock 30 g 11 mS 42 RUGGEDCOM RX5000 Installation Manual 01 2021 C7...

Страница 52: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: