Installing the Device
2.4.3 Disabling Line-to-Ground Transient Protection
2.4.3
Disabling Line-to-Ground Transient Protection
All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases
where users require the inputs to be isolated from ground, remove the ground braid
between Surge and Chassis Ground. All line-to-ground transient protection circuitry
will be disabled.
Figure 2.12
Surge Ground/Chassis Ground Connection
18
RUGGEDCOM RS969
Installation Manual, 01/2021, C79000-G8976-1038-03