Installing the Device
2.4 Connecting Power
The proper relay connections are as follows:
2
1
4
3
Figure 2.2
Failsafe Alarm Relay Wiring
Pin
Description
1
Normally Closed
2
Common
3
Normally Open
2.4
Connecting Power
The RUGGEDCOM RS969 is equipped with either a Mini or M23 A-coded male power
supply input connector. The Mini power connector only has four terminals, so only
one power supply source is allowed to connect to the RUGGEDCOM RS969 with
the Mini power connector. The M23 power connector has five terminal pins, which
allows for two power supply sources to be connected to the RUGGEDCOM RS969
with the M23 power connector.
When equipped with an M23 power connector, the RUGGEDCOM RS969 supports
dual redundant power supplies:
Power Supply 1 (PS1)
and
Power Supply 2 (PS2)
.
2.4.1
Power Supply Connector Pin-Out
The following is the pin-out for the Mini and M23 A-coded power supply connector:
Mini Power Supply Connector
2
4
3
1
Figure 2.3
Mini Power Supply Connector
12
RUGGEDCOM RS969
Installation Manual, 01/2021, C79000-G8976-1038-03