Image processing
4.2 Code verification
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
67
4.2.8
Verification result
%V (upper-case "V") gives you a standard test report with all valid grades and evaluations.
This report is automatically adapted to the verification standard stored in the program.
All field values (grades and evaluations) are separated by a semicolon.
The field names are not part of the standard report.
If you do not require all the grades and/evaluations, the test report can be composed of the
individual tags %Q.. or %q..
Note
Combination of multicode and verification
•
If you select the verification task "uncalibrated", all the data matrix codes found are
evaluated according to ISO 16022 and all barcodes according to ISO/IEC 15416. The
evaluation is, however, made without any basic calibration. The standard test report is
automatically adapted to the standard being used for each code.
•
If you select a specific verification method, this is used for all matching code types, other
code types are not evaluated.
•
If a read code has not been evaluated, the output of the verification report for this code is
skipped.
Note
Verification error
Whenever a verification error occurs, all quality grades are output as "E" and the error
number is output instead of the quality values. Please see Read and verification error
messages (Page 342) for information on the meaning of the error number.
Содержание SIMATIC MV420
Страница 2: ......
Страница 408: ...List of abbreviations and acronyms SIMATIC MV420 SIMATIC MV440 406 Operating Instructions 04 2013 A5E02371045 06 ...
Страница 418: ...Glossary SIMATIC MV420 SIMATIC MV440 416 Operating Instructions 04 2013 A5E02371045 06 ...
Страница 423: ......