SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
99
Network and system interfacing
5
5.1
Overview
You have the following options for the acquisition and processing of recognition values
during system configuration of the reader:
●
PROFIBUS DP-V1 with ASM 456 and FB45 or Ident profile
●
PROFINET IO with RF180C and FB45 or Ident profile
●
Onboard PROFINET IO and FB79 or Ident profile
●
RS232 interface *)
●
Ethernet interface (TCP/IP)
●
SIMATIC S7-300 with ASM475 and FB45
●
SIMATIC ET 200M with ASM475 and FB45
●
SIMATIC ET200pro with RF170C and FB45
●
EtherNet/IP with RF181EIP
*
)
With SIMATIC MV420 only available when the ASM interface is not being used.
Note
No separate ASM connector in the SIMATIC MV420
There is no separate ASM connector in the SIMATIC MV420. The ASM interface is
implemented via the digital I/O cable and must be connected via this when required. The
applications listed below are also available with SIMATIC MV420.
Other possible combinations include:
●
Reader and RFID reader on an ASM 456
●
Auto-trigger
●
Image display via WinCC flexible
●
External lamp