Process interfacing via an automation system (PLC, PC)
10.3 Control with FB 45 and Ident profile
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
257
Table 10- 25 Moby_CMD
Command
[hex]
Sub_
Command
[hex]
Length
[dez]
Address_
MDS [hex]
DAT_DB_num
ber
[dez]
DAT_DB_addr
ess
[dez]
Number of the
data DB (for
example 48)
Pointer to the
start word
(for example 0)
01
-
Total length of
the XMATCH
user data + 4
0
Pointer to the user data to be
sent to the reader.
Table 10- 26 PIB_COMMAND
Parameter
Value
CMD
0x70
OffsetBuffer
0x00
UID
0x00
Length
Total length of the XMATCH user data + 4
StartAddress
0x00
Table 10- 27 Command data area (FB45: Data DB, RFID standard profile: TXBUF or RXBUF)
Address
Value
Meaning
0x0000
0x07
Command identifier XMATCH
0x0001
0x00
Reserved
0x0002
…
0xN
See chapter "Control via TCP/IP
XMATCH user data