Device maintenance and repair
7.4 Installing the software
SIMATIC IPC427D
98
Operating Instructions, 05/2017, A5E31347215-AB
7.4.1.4
Windows Embedded Standard 7
General installation procedure
If your software becomes corrupt for any reason, you can re-install it using the supplied USB
stick. The USB stick contains an image file for the device memory with the original software
package (operating system with installed hardware drivers).
Note
You require a USB keyboard, a monitor and the supplied USB stick to reinstall the operating
system. Before performing the new installation, you should check the date and time set in
the BIOS Setup, "Main" menu, and correct these if necessary.
To be able to use the Enhanced Write Filter (EWF), the operating system must be installed
in MBR mode.
You can change the language using the supplied USB stick. The USB stick contains the
required language packages and help for changing the system language.
Note
Note the license terms of Windows Embedded Standard 7
Note the license terms for Windows Embedded Standard 7 and especially the extended
software terms of the Siemens AG.
You can find the license terms in the delivered document "MICROSOFT SOFTWARE
LICENSE TERMS for Windows Embedded Standard 7" and in the system drive under
\Windows\System32\license.rtf.
Procedure - Change system language
1.
Connect the supplied USB stick to a free USB port of the device.
2.
Restart the device and press "ESC" to access the BIOS.
3.
Switch to the "Boot" menu and select the setting "USB Boot" = "Enabled".
4.
Switch to the "Exit" menu and select "Exit Saving Changes".
5.
Restart the device and press the "ESC" key and then enter the "Boot Manager" menu.
6.
In the "Legacy USB" area, select the boot menu of the USB stock and press "Enter" to
boot from this.