Brief description of ASM hardware
A.1 ASM 475
FC 45
A-2
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
Write/read device / reader connection system
Prefabricated write/read device connection cables are available in various lengths for the
ASM 475. The cores at the open end to the ASM/communication module are marked with
connection numbers. When making the connections, make sure that the cable shield is led
over the shield connecting element. See MOBY manual on configuration, installation and
service for more information.
Input parameters for ASM 475
The assignment is made in UDT 10 (see Section "Parameter data block").
Table A-1
Input parameters for ASM 475
Address
Name
Permissible values
Comment
+0.0
ASM_address
256, 272, 288 ... 752
256, 272, 288, ...
2
256, 260, 264, ...
1
Centralized layout:
Addresses are specified by HW
Config (see Section "Addressing of
MOBY channels"). Distributed
layout:
Automatic or manual address
assignment
+2.0
ASM_channel
1, 2
2 parallel channels
+8.0
MDS_control
B#16#0, 1
Enable/disable presence check
+9.0
ECC_mode
TRUE, FALSE
TRUE is only permitted when
MOBY_mode is parameterized with 1.
+9.1
RESET_long
TRUE, FALSE
TRUE,
if MOBY_mode = 5 (MOBY U or RF300)
+10.0
MOBY_mode
B#16#1, 5, A, B
MOBY I/E/F/U
1
/D
1
+11.0
scanning_time
B#16#00 ... FF
A value other than 00 is only
recommended when MOBY_mode was
parameterized appropriately (see
Section "INPUT parameters").
+12.0
option_1
B#16#00, 02, 04, ...
See Section "INPUT parameters"
+13.0
distance_limiting
B#16#05, 0A, 0F, 14,
19, 1E, 23
MOBY U
1
/D
1
(see Section "INPUT
parameters")
+14.0
multitag
B#16#1
MOBY U
1
/D
1
or RF300
1
+15.0
field_ON_control
B#16#0, 1, 2
MOBY U
1
/D
1
(see Section "INPUT
parameters")
+16.0
field_ON_time
B#16#00 ... FF
MOBY U
1
/D
1
(see Section "INPUT
parameters")
1) valid only for 6GT2 002-0GA10