Parameterizing
3.1 Parameter data block
FC 45
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
3-5
Variable
Description
MOBY U:
Scanning_time describes the standby time for the MDS. If the MDS receives an additional command
before scanning_time has expired, this command can be executed immediately. If the MDS receives
a command after scanning_time has expired, command execution is delayed by sleep_time of the
MDS.
Scanning_time should only be set when both of the following conditions exist.
•
The MDS uses several commands
and
•
command execution must be concluded within a minimum time.
00 hex = no standby time (default)
01 hex = 7ms standby time
02 hex = 14ms standby time
:
C8 hex = 1400ms standby time
Remember:
Scanning_time affects the life of the battery. The longer scanning_time is, the shorter the life of the
battery. For precise calculations, see the MOBY U manual for configuration, mounting and service.
scanning_time
MOBY D or RF300: 00 hex (reserved)
option_1
This byte is bit-coded. Its standard value is B#16#0. It can be used for special control on the ASM.