Brief description of ASM hardware
A.7 ASM 850
FC 45
A-30
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
Input parameters for ASM 850
The assignment is made in UDT 10 (see Section "Parameter data block").
Table A-18 Input parameters for ASM 850
Address
Name
Permissible
values
Comment
+0.0
ASM_address
256, 264, 272,
280, ...
Each ASM 850 occupies 8 byte
of I/O in the I/O area of the
control unit
+2.0
ASM_channel
1
1 channel
+8.0
MDS_control
B#16#0, 1
0= no presence check
1= presence check
+9.0
ECC_mode
FALSE
No ECC driver
+9.1
RESET_long
FALSE
(no MOBY U)
+10.0
MOBY_mode
B#16#A, B
Only MOBY F parameterization
+11.0
scanning_time
B#16#00
No parameterization of the
scanning time
+12.0
option_1
B#16#00, 01, 04,
08
(See Section "INPUT
parameters")
+13.0
distance_limiting
B#16#0
+14.0
multitag
B#16#1
+15.0
field_ON_control
B#16#0
+16.0
field_ON_time
B#16#0
Not relevant (no MOBY U)
Table of commands for ASM 850
The assignment is made in UDT 20 using the "Command" variable (see Section "Command
parameter settings").
Table A–18 Commands of the ASM 850
Command code
normal
Chained
Description
01
41
Write to MDS
02
42
Read MDS; read fixed code
03
43
Initialize MDS
0A
4A
Antenna on/off
The command table is valid for the FB 45. No commands are transferred to the ASM when
fixed-code MDSs are processed with the process image.
Switch settings, interfaces and indicators of the ASM 850
See Section "Switch settings, interfaces and indicators of the ASM 454" in Chapter "ASM
454"