Technical data
•
At "0" to "1"
Typ. 3 ms
•
At "1" to "0"
Typ. 3 ms
Input characteristic
According to IEC 61131, Type 3
Connection of 2-wire proximity switches
Supported
•
Permitted quiescent current
Max. 1.5 mA
9.1.4
Parameter overview digital inputs
Parameters for 8 DI DC 24V 4×M12 (6ES7141-6BF00-0AB0) and for 8 DI DC 24V 8×M12
(6ES7141-6BG00-0AB0)
Parameter
Range of values
Default setting
Range of effectiveness
Group diagnostics
•
Disable
•
Enable
Disable
Device
Diagnostics: Missing 1L+
•
Disable
•
Enable
Disable
Device
Diagnostics: Wire break at inputs 0 to 7
(channels 0 to 7)
•
Disable
•
Enable
Disable
Channel
Diagnostics: Short-circuit to M, inputs
0,4/1,5/2,6/3,7 (channels 0,4/1,5/2,6/3,7)
•
Disable
•
Enable
Disable
Channel group
Parameters for 16 DI DC 24V 8×M12 (6ES7141-6BH00-0AB0)
Parameter
Range of values
Default setting
Range of effectiveness
Group diagnostics
•
Disable
•
Enable
Disable
Device
Diagnostics: Missing 1L+
•
Disable
•
Enable
Disable
Device
Diagnostics: Wire break at inputs 0 to 15
(channels 0 to 15)
•
Disable
•
Enable
Disable
Channel
Diagnostics: Short-circuit to M, inputs
0,8/1,9/2,10/3,11/4,12/5,13/6,14/7,15
(channels
0,8/1,9/2,10/3,11/4,12/5,13/6,14/7,15)
•
Disable
•
Enable
Disable
Channel group
121
I/O device digital inputs/digital outputs
9.1 I/O device digital inputs
ET 200eco PN
Operating Instructions, 06/2022, A5E01250250-AN
Содержание SIMATIC ET 200eco PN
Страница 233: ...ET 200eco PN Operating Instructions 06 2022 A5E01250250 AN 234 Dimensional drawings C ...
Страница 265: ...266 ET 200eco PN Operating Instructions 06 2022 A5E01250250 AN Open Source Software ...