Getting Started: Communication between a CPU 416-2 PCI and an S7-400
Windows Automation Center, WinAC Slot Version 4.0
Hardware Installation and Operating Manual, Edition 02/2006, A5E00273194-02
99
7.10
Step 8: Communication
Integrate the appropriate communication blocks (e.g., Put/Get) into your user
program.
7.11
Going Online with STEP 7 to the CPU 41x-2 PCI
Connecting STEP 7 to the CPU 41x-2 PCI on the Same Computer
Proceed as follows if you want to configure STEP 7 for communication with the
CPU 41x-2 PCI on the same computer.
1. Open the interface tool in WinAC Slot using the following command:
CPU >
Set PG/PC Interface
.
2. Perform the following steps to set up STEP 7 as a local access point:
– In the Access Point of the Application field, select
S7ONLINE (STEP 7)
(see
figure).
– In the Interface Parameter Assignment Used field, select "PC internal (local)"
as the interface parameter.