7 Operation at Use of a PC
7.3 Configuration of the Device
123
SENTRON PAC5100/5200, 7KM5212/5412, Device Manual
E50417-H1040-C568-A1, Edition 03.2015
7.3.3.1.3
LEDs
Default Settings and Setting Options of the LEDs
To change the outputs of the LEDs H1, H2, and ERROR, proceed as follows:
✧
In the navigation window, select the
Operational
menu, then the
Process connections
submenu and
click
LEDs
.
Figure 7-26
Configure Tab, LEDs Input/Output Window
Table 7-5
LED Settings
LED
Default Setting
Setting Options
RUN
Device ready
Not settable
ERROR
-none-
Errors are signaled as parameterized (only
error indications can be parameterized).
Acc. to list box
(see Operating Parameters)
H1
-none-
Acc. to list box
(see Operating Parameters)
H2
Indication inverted
no
no
yes