Overview and definition of terms
1.7 "Override" mode
Fail-safe operation of the Mobile Panel 277F IWLAN
Function Manual, 08/2008, 6AV6691-1FQ01-2AB0
25
Sample configuration
352),VDIH
①
Protective fence
②
Switch for activating "override" mode
③
Transponder for logging on at the effective range
④
Foot grating for access monitoring
⑤
HMI device
⑥
Machine that will be operated
Activation of the "override" mode
The operator activates "Override" mode in the following manner:
1.
The operator enters the protected area through a light barrier or across a foot grating.
The protective device is activated.
2.
The operator logs on at the effective range in which the override switch is located.
3.
The operator activates the override switch.
"Override" mode is now active until either the operator deactivates "Override" mode with the
override switch or until he leaves the protected area.