Operation
6.2 Typical applications
Fail-safe operation of the Mobile Panel 277F IWLAN
Function Manual, 08/2008, 6AV6691-1FQ01-2AB0
95
Result case 2: does not return to the effective range on time
The "Effective range exited without logoff" dialog box opens.
The HMI device triggers a local rampdown and log off from the effective range.
As long as the operator does not confirm log off from the effective range, the dialog box is displayed
on the HMI device. The operator is not able to interact with the machine. The effective range remains
in use.
When the operator has confirmed logoff from the effective range, the HMI device is logged off from
the effective range and the effective range is then released for logon for other HMI devices.
6$)(
3:5
&20
51*
%$7
6.2.6
"Override" mode
6.2.6.1
Activating "override" mode
Initial situation
The system has the protective devices specified for "Override" mode.
6$)(
3:5
&20
51*
%$7
Action
The operator enters a protected zone.
The operator logs the HMI device on in the effective range in which the override switch is located.
The operator activates the override switch.
Result
"Override" mode is active.
The "Effective range quality" object is displayed entirely in green.
The transponders are not evaluated for detection of the effective range.
The operator can operate the machine in the entire override range as if he were in the middle of the
effective range.
No other HMI device can log onto the effective range.
6$)(
3:5
&20
51*
%$7