8.7
Switching properties
The switching properties listed below apply to the SCALANCE XR-300WG.
Switching properties
Aging time
Can be configured (default value: 30 seconds)
Maximum frame size
2048
Max. number of learnable address‐
es
16382
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
CoS acc. to IEEE 802.1Q
Yes
QoS priority queues
4
Switching technique
Store and forward
Latency
10 microseconds
Full wire speed switching
Frame length (bytes)
Number of frames per second
At 100 Mbps
At 1000 Mbps
At 10000 Mbps
64
148810
1488095
14136931
128
84459
844595
8023670
256
45290
452899
4415773
512
23496
234962
2320257
1024
11973
119732
1189835
1280
9615
96154
955529
1518
8127
81274
807664
Note
The number of SCALANCE XR-300WG modules connected in a line influences the frame delay.
When a frame passes through IE switches of the SCALANCE XR-300WG product line, it is delayed
by the store and forward function of the device:
• with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps)
• with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps)
This means the more devices of the SCALANCE XR-300WG product line that the frame passes
through, the longer the frame delay.
Technical specifications
8.7 Switching properties
SCALANCE XR-300WG
86
Operating Instructions, 03/2021, C79000-G8976-C454-07
Содержание SCALANCE XR-300WG
Страница 10: ...Safety notices SCALANCE XR 300WG 10 Operating Instructions 03 2021 C79000 G8976 C454 07 ...
Страница 16: ...Recommendations on network security SCALANCE XR 300WG 16 Operating Instructions 03 2021 C79000 G8976 C454 07 ...
Страница 98: ...Approvals SCALANCE XR 300WG 98 Operating Instructions 03 2021 C79000 G8976 C454 07 ...