Legal information
Warning notice system

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage 
to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices 
referring only to property damage have no safety alert symbol. These notices shown below are graded according to 
the degree of danger.

DANGER

indicates that death or severe personal injury will result if proper precautions are not taken.

WARNING

indicates that death or severe personal injury may result if proper precautions are not taken.

CAUTION

indicates that minor personal injury can result if proper precautions are not taken.

NOTICE
indicates that property damage can result if proper precautions are not taken.

If more than one degree of danger is present, the warning notice representing the highest degree of danger will be 
used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property 
damage.

Qualified Personnel

The product/system described in this documentation may be operated only by personnel qualified for the specific 
task in accordance with the relevant documentation, in particular its warning notices and safety instructions. 
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and 
avoiding potential hazards when working with these products/systems.

Proper use of Siemens products

Note the following:

WARNING

Siemens products may only be used for the applications described in the catalog and in the relevant technical 
documentation. If products and components from other manufacturers are used, these must be recommended or 
approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance 
are required to ensure that the products operate safely and without any problems. The permissible ambient 
conditions must be complied with. The information in the relevant documentation must be observed.

Trademarks

All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may 
be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaimer of Liability

We have reviewed the contents of this publication to ensure consistency with the hardware and software described. 
Since variance cannot be precluded entirely, we cannot guarantee full consistency.  However, the information in this 
publication is reviewed regularly and any necessary corrections are included in subsequent editions.

Siemens AG
Digital Industries
Postfach 48 48
90026 NÜRNBERG
GERMANY

C79000-G8976-C454-07
Ⓟ 03/2021 Subject to change

Copyright © Siemens AG 2017 - 2021.
All rights reserved

Содержание SCALANCE XR-300WG

Страница 1: ...erating Instructions 03 2021 C79000 G8976 C454 07 Introduction 1 Safety notices 2 Recommendations on network security 3 Description of the device 4 Installation 5 Connecting up 6 Upkeep and maintenance 7 Technical specifications 8 Dimension drawings 9 Approvals A ...

Страница 2: ...re those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used ...

Страница 3: ... standard 32 4 7 2 PoE properties of the devices 32 4 7 3 Power transfer and pin assignment ports P1 P24 33 4 7 4 Power transfer and pin assignment ports P25 and P26 34 4 7 5 Configuration 34 5 Installation 35 5 1 Safety notices for installation 35 5 2 Types of installation 39 5 3 19 rack mounting 40 5 4 DIN rail mounting wall mounting 42 5 5 Inserting and removing pluggable transceivers 46 5 5 1 ...

Страница 4: ...ions of the SCALANCE XR324WG 71 8 1 1 24 VDC variant 71 8 1 2 240 VAC variant 73 8 2 Technical specifications of SCALANCE XR326 2C PoE WG 74 8 3 Technical specifications of the SCALANCE XR328 4C WG 76 8 3 1 24 VDC variant 76 8 3 2 240 VAC variant 78 8 4 Technical specifications of the SCALANCE XR328 4C WG GE 80 8 4 1 24 VDC variant 80 8 4 2 240 VAC variant 82 8 5 Mechanical stability in operation ...

Страница 5: ...nformation applies to all product groups within the product line the term SCALANCE X 300 is used SCALANCE X 300 Product group If information applies to all devices and variants of a product group the term SCALANCE XR 300WG is used SCALANCE XR 300WG Device If information relates to a specific device the device name is used e g SCALANCE XR328 4C WG Device group If information applies to all SCALANCE...

Страница 6: ... Support https support industry siemens com cs ww en ps 24678 man Further documentation In the system manuals Industrial Ethernet PROFINET Industrial Ethernet and Industrial Ethernet PROFINET passive network components you will find information on other SIMATIC NET products that you can operate along with the devices of this product line in an Industrial Ethernet network There you will find among ...

Страница 7: ...ducts and solutions constitute one element of such a concept Customers are responsible for preventing unauthorized access to their plants systems machines and networks Such systems machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures e g firewalls and or network segm...

Страница 8: ... to prevent unauthorized persons from accessing confidential data in the device memory To do this restore the factory settings on the device Recycling and disposal The products are low in pollutants can be recycled and meet the requirements of the WEEE directive 2012 19 EU for the disposal of electrical and electronic equipment Do not dispose of the products at public disposal sites For environmen...

Страница 9: ...plosion WARNING EXPLOSION HAZARD Do not open the device when the supply voltage is turned on Safety notices when using the device according to Hazardous Locations HazLoc and FM If you use the device under HazLoc or FM conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion This equipment is suitable for use in Class I...

Страница 10: ...Safety notices SCALANCE XR 300WG 10 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 11: ...ks use additional devices with VPN functionality to encrypt and authenticate the communication No product liability will be accepted for operation in a non secure infrastructure Terminate management connections correctly WBM Telnet SSH etc Physical access Restrict physical access to the device to qualified personnel Lock unused physical ports on the device Unused ports can be used to gain forbidde...

Страница 12: ... contains a pre installed certificate with key Replace this certificate with a self made certificate with key We recommend that you use a certificate signed either by a reliable external or by an internal certification authority You can install the certificate via the WBM System Load and Save Use the certification authority including key revocation and management to sign the certificates Make sure...

Страница 13: ...s If no unrestricted access is necessary restrict access with SNMP Use the authentication and encryption mechanisms of SNMPv3 Use secure protocols when access to the device is not prevented by physical protection measures If you require non secure protocols and services operate the device only within a protected network area Restrict the services and protocols available to the outside to a minimum...

Страница 14: ...ls local access via a local network The following is a list of all available protocols and their ports through which the device can be accessed Protocol Protocol Port number Default port sta tus Configurable port Authentication Encryption DHCPv4 Server UDP 67 Closed No No DHCPv4 Client UDP 68 Open No No Discard TCP 9 Open filtered No No Echo IP UPD TCP 9 Open No No EtherNet IP TCP 44818 UDP 2222 U...

Страница 15: ...813 Closed Yes Yes SMTP TCP 25 TCP 465 Closed Yes Yes SNMP UDP 161 Open Yes Yes when con figured SSH TCP 22 Open Yes Yes Syslog UPD 514 TCP 6514 Closed Yes Yes TELNET TCP 23 Open Yes No TFTP UDP 69 Open No No 1 Port number can be configured via the WBM Recommendations on network security SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 15 ...

Страница 16: ...Recommendations on network security SCALANCE XR 300WG 16 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 17: ...E WG 1 x 100 to 240 V AC power supply connector at rear 24 x 10 100 1000 Mbps RJ45 ports 2 x combo ports 2 x 100 1000 10000 Mbps RJ45 ports 2 x pluggable transceiver slots with 1000 10000 Mbps Grounding bolt on the back of the device Power over Ethernet at 26 ports 6GK5 326 2QS00 3AR3 1 x 100 to 240 V AC power supply connector at rear 24 x 10 100 1000 Mbps RJ45 ports 2 x combo ports 2 x 100 1000 1...

Страница 18: ...3 240 V AC variant 24 x 10 100 Mbps RJ45 ports 4 x combo ports 4 x 10 100 1000 Mbps RJ45 ports 4 x pluggable transceiver slots with 1000 Mbps 1 x 100 to 240 V AC power supply connector at rear Grounding screw on the front of the device Reduced approvals 6GK5 328 4FS00 3RR3 24 VDC variant GE 1 24 x 10 100 1000 Mbps RJ45 ports 4 x combo ports 4 x 10 100 1000 Mbps RJ45 ports 4 x pluggable transceiver...

Страница 19: ...trical connectors Number of pluggable transceiver slots XR3 C PoE WG Power over Ethernet Components of the product The following components are supplied with a SCALANCE XR 300WG One device One product DVD with documentation and software The following components are also supplied with a 24 VDC variant Two 2 terminal blocks for the power supply 24 V DC The following components are also supplied with...

Страница 20: ...e damaged parts this can lead to the following problems Injury to persons Loss of the approvals Violation of the EMC regulations Damage to the device and other components Use only undamaged parts 1 Make sure that the package is complete 2 Check all the parts for transport damage Description of the device 4 1 Product overview SCALANCE XR 300WG 20 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 21: ...Grounding screw Electrical ports with port LEDs Combo port ports with port LEDs Integrated brackets for 19 rack mounting 24 VDC power supply redundant Serial interface RESET button LED display The F LED for faults The RM LED for the redundancy manager function LED L for the power supply Description of the device 4 2 Device views SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07...

Страница 22: ...cal ports with port LEDs Combo port ports with port LEDs Integrated brackets for 19 rack mounting 240 V AC power supply rear Grounding screw Serial interface RESET button LED display The F LED for faults The RM LED for the redundancy manager function LED L for the power supply Description of the device 4 2 Device views SCALANCE XR 300WG 22 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 23: ... with port LEDs Integrated brackets for 19 rack mounting 240 V AC power supply rear Grounding bolts rear Connection for PoE power expansion through external power supply units rear Serial interface RESET button LED display The F LED for faults The RM LED for the redundancy manager function LED L for the power supply Description of the device 4 2 Device views SCALANCE XR 300WG Operating Instruction...

Страница 24: ... m For America 6ES7 900 0DA00 0XA0 Power cable 100 to 240 VAC straight 3 m For Italy 6ES7 900 0EA00 0XA0 Power cable 100 to 240 VAC straight 3 m For China 6ES7 900 0FA00 0XA0 PoE power supply Type Input voltage Output voltage Output current Article number SCALANCE PSR9230PoE 100 240 VAC 50 60 Hz 54 V DC 4 A 6GK5 923 0PS00 2RA3 Active plug in transceiver SFP 100 Mbps With active plug in transceiver...

Страница 25: ...x 1000 Mbps LC port optical for glass FO cable single mode up to max 30 km 6GK5 992 1AM30 8AA0 SFP992 1LH 1 x 1000 Mbps LC port optical for glass FO cable single mode up to max 40 km 6GK5 992 1AN00 8AA0 SFP992 1LH 1 x 1000 Mbps LC port optical for glass FO cable single mode up to max 70 km 6GK5 992 1AP00 8AA0 SFP992 1ELH 1 x 1000 Mbps LC port optical for glass FO cable single mode up to max 120 km...

Страница 26: ...A0 SFP992 1BX10R 1 x 1000 Mbps LC port optical for glass FO single mode with max 10 km transmits at 1310 nm receives at 1550 nm 6GK5 992 1AM00 8RA0 SFP transceiver Type Properties Article number SFP993 1 1 x 10 Gbps LC port optical for glass FO cable multimode up to max 550 m 6GK5 993 1AT00 8AA0 SFP993 1LD 1 x 10 Gbps LC port optical for glass FO cable single mode up to max 10 km 6GK5 993 1AU00 8A...

Страница 27: ...er Green On The device is a redundancy manager The ring is working without problems monitoring is activated Green Flashing The device is a redundancy manager An interruption has been detected on the ring and the device has switched through 4 4 3 LED L The LED L shows whether the power supply is connected LED color LED status Meaning Green Lit The power supply is connected With a redundant power su...

Страница 28: ...atus Meaning Yellow Flashing Data transfer at the port Off No data transfer at the port Pluggable transceiver slots There is an LED for each plug in transceiver slot LED color LED status Meaning Green Lit Link exists Yellow Flashing Data transfer at the port Off No link exists Description of the device 4 4 LED display SCALANCE XR 300WG 28 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 29: ...ertent reset can cause disturbances and failures in the configured network Requirement The device is in operation The function Reset to factory defaults is enabled for the RESET button Note Reset despite disabled RESET button If you have disabled the Reset to Factory Defaults function for the RESET button in the configuration this does not apply during the startup phase see section Restoring the f...

Страница 30: ...nds If you release the button after approximately 12 seconds the device is restarted and the factory settings are restored If you release the button before the 12 seconds have elapsed the reset is canceled Enabling and disabling the button In the configuration you can enable or disable the button function Description of the device 4 5 RESET button SCALANCE XR 300WG 30 Operating Instructions 03 202...

Страница 31: ...abeled with the port name PxC Setting the mode The following modes can be configured for a combo port Mode 1 auto The SFP transceiver port has priority As soon as an SFP transceiver is plugged in an existing connection at the fixed RJ 45 port is terminated If no SFC transceiver is plugged in a connection can be established via the fixed RJ 45 port Mode 2 rj45 The fixed RJ 45 port is independent of...

Страница 32: ...ange according to the standard Note the values specified for the power of the power source so that the power supply is ensured at the power consumers according to the standard PoE class Power supplied by the pow er source Available power at the pow er source Type Standard Designation 0 15 4 W 12 95 W 1 IEEE802 3af PoE 1 4 3 84 W 2 7 6 49 W 3 15 4 W 12 95 W 4 30 25 5 W 2 IEEE802 3at PoE 5 45 40 W 3...

Страница 33: ...rt PoE classes 0 to 6 They supply connected devices with up to 60 W per port according to IEEE802 3af IEEE802 3at and IEEE802 3bt Power The maximum output power can be configured e g using the WBM If the maximum power is exceeded the supply is switched off port by port The order in which the ports are switched off depends on the priority of the ports The priority can be configured e g using the WB...

Страница 34: ...sitive power supply Pin 4 Positive power supply Pin 5 Positive power supply Pin 6 Positive power supply Pin 7 Negative power supply Pin 8 Negative power supply 4 7 5 Configuration How you activate and configure PoE is described in the configuration manuals see section Introduction section Documentation on configuration Description of the device 4 7 Power over Ethernet SCALANCE XR 300WG 34 Operatin...

Страница 35: ...uired safety measures at an ambient temperature higher than 40 WARNING If the device is installed in a cabinet the inner temperature of the cabinet corresponds to the ambient temperature of the device Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Replacing components may impair suitability for Class 1 Division 2 or...

Страница 36: ...P54 in accordance with EN IEC 60079 15 WARNING If the temperature of the cable or housing socket exceeds 70 C or the branching point of conductors exceeds 80 C special precautions must be taken If the equipment is operated in an air ambient in excess of 50 C to 60 C only use cables with a permissible operating temperature of at least 85 C Safety notices when using according to FM If you use the de...

Страница 37: ...ing safety notices in addition to the general safety notices for protection against explosion WARNING Open equipment The devices are open equipment according to the standard IEC 61010 2 201 or UL 61010 2 201 CSA C22 2 No 61010 2 201 To fulfill requirements for safe operation with regard to mechanical stability flame retardation stability and protection against contact the following alternative typ...

Страница 38: ...evice and can lead to premature aging of the IE switch and its cabling Provide suitable shade to protect the IE switch against direct sunlight Note During installation and operation keep to the installation guidelines and safety notices described in this document and in the system manuals Industrial Ethernet PROFINET Industrial Ethernet and Industrial Ethernet PROFINET passive network components Y...

Страница 39: ...ounting Installation position for PoE variants Horizontal installation position is recommended for PoE variants inscription is in the read direction Vertical installation position is also permissible Installation 5 2 Types of installation SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 39 ...

Страница 40: ...eps below 1 Position the device at the required location in the 19 rack 2 Screw the two brackets to the 19 rack in each case with 2 securing screws 3 Connect the cables see section Connecting up Page 49 Uninstalling To remove the device from a 19 rack follow the steps below 1 Disconnect all connected cables 2 Undo the securing screws on the mounting brackets 3 Remove the device from the 19 rack In...

Страница 41: ...ng of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should b...

Страница 42: ... wall mounting are described in this section because a DIN rail is required also for wall mounting Note that PoE variants have a different guide rail Installation 5 4 DIN rail mounting wall mounting SCALANCE XR 300WG 42 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 43: ...he housing there are two guides for receiving a DIN rail Push the DIN rail into the guides as shown in the following figure Figure 5 2 Connecting SCALANCE and DIN rail Installation 5 4 DIN rail mounting wall mounting SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 43 ...

Страница 44: ... the wall or other surface for attaching the DIN rail Screwing in the DIN rail Screwing on the standard mounting rail for PoE variants 3 Connect the cables see section Connecting up Page 49 Installation 5 4 DIN rail mounting wall mounting SCALANCE XR 300WG 44 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 45: ...w the steps below 1 Remove all connected cables 2 Loosen the screws of the DIN rail 3 Take the DIN rail out of the housing Installation 5 4 DIN rail mounting wall mounting SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 45 ...

Страница 46: ...mentation for SFP transceivers You will find detailed information in the operating instructions of the pluggable transceivers see the chapter Introduction Page 5 section Additional documentation 5 5 2 Using a pluggable transceiver SFP Follow the steps below to insert a pluggable transceiver 1 Remove the sealing plug of the pluggable transceiver slot 2 Close the clip of the pluggable transceiver 3 ...

Страница 47: ...ove a pluggable transceiver 1 Remove the connecting cable of the pluggable transceiver 2 Open the clip of the pluggable trabsceiver 3 Remove the pluggable transceiver from the pluggable transceiver slot Note Do not use force It must be possible to remove the pluggable transceiver easily and without applying any force 4 Close the pluggable transceiver slot with a sealing plug Installation 5 5 Inser...

Страница 48: ...Installation 5 5 Inserting and removing pluggable transceivers SCALANCE XR 300WG 48 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 49: ... NEC Class 2 as described by the National Electrical Code r ANSI NFPA 70 If the equipment is connected to a redundant power supply two separate power supplies both must meet these requirements WARNING Do not remove or replace while circuit is live when a flammable or combustible atmosphere is present Note No light power measurement PROFINET diagnostics The devices do not support diagnostics with l...

Страница 50: ...t explosion WARNING Take measures to prevent transient voltage surges of more than 40 of the rated voltage This is the case if you only operate devices with SELV safety extra low voltage WARNING Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 119 V WARNING EXPLOSION HAZARD Do not press the RESET button if there is a potentially explo...

Страница 51: ...rnet uses RJ 45 connected technology with MDI X assignment Pin assignment The following table shows the pin assignment of the RJ45 connectors Pin number Assignments for ports up to RJ45 connector Max 100 Mbps Max 1000 Mbps Max 10000 Mbps Pin 1 RD D1 D1 Pin 2 RD D1 D1 Pin 3 TD D2 D2 Pin 4 n c Not connec ted D3 D3 Pin 5 n c Not connec ted D3 D3 Pin 6 TD D2 D2 Pin 7 n c Not connec ted D4 D4 Pin 8 n c...

Страница 52: ...means the automatic detection negotiation of the transmission rate and the operating mode of ports at the opposite end This makes it possible to configure different devices automatically Two components connected to a link segment can exchange information about the transfer and can adapt their settings to each other The mode with the highest possible speed is set Note If a port is set permanently t...

Страница 53: ... before connecting No residues of processing may remain on the connector Only remove the dust caps of optical transceivers and pre configured cables shortly before connecting the cables Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps LC connector technology The attachment to Industrial Ethernet uses LC connector technology Lucent...

Страница 54: ... TWIN wire end ferrule 0 75 1 mm2 AWG 20 18 Stripped length of the cable 8 10 mm Wire end ferrule according to DIN 46228 with plastic ferrule 8 10 mm AWG American Wire Gauge See note Wire end ferrules Note Wire end ferrules Use crimp shapes with smooth surfaces such as provided by square and trapeze shaped crimp cross sections Crimp shapes with wave shaped profile are unsuitable Connecting up 6 3 ...

Страница 55: ...ording to ANSI UL 248 1 or CSA C22 2 No 248 1 Classes R J L T or CC Suitable for the protection of DC power supply circuits In other areas Suitable for DC min 60 V max 5 A Breaking current at least 10 kA Approval in compliance with IEC 60127 1 EN 601127 1 Switch off characteristics B or C for circuit breakers and fuses Suitable for the protection of DC power supply circuits You do not need to fuse...

Страница 56: ...G Hans Dehn Str 1 Postfach 1640 D 92306 Neumarkt Germany Information on the power supply The power supply is connected using two 2 pin plug in terminal blocks The terminal blocks ship with the device The power supply can be connected redundantly Both inputs are isolated There is no distribution of load When a redundant power supply is used the power supply unit with the higher output voltage suppl...

Страница 57: ...ge Make sure that the connector cannot be released accidentally by pulling on the connecting cable Lay the cables in cable ducts or cable channels and secure the cables where necessary with cable ties Note Use in IT networks When used in IT networks the power supply 240 VAC also applies to the connected IT network Phase to phase Information on the power supply The power supply is connected using a...

Страница 58: ...tion of the device installation connector Figure 6 3 Position of the device installation connector in PoE variants Connecting up 6 5 Power supply 240 VAC SCALANCE XR 300WG 58 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 59: ...upply units in a Restricted access area according to IEC 62368 1 WARNING Only use supplied cable to connect power expansion A maximum of two SCALANCE PSR9230PoE power supply units are permissible for power expansion of the devices For the connection use the supplied power cable article no A5E49168671 The cable is pre assembled for connection to a switch of the SCALANCE XR 300PoE WG device group To...

Страница 60: ...PoE power supply is connected via a 2 pin plug in terminal block The connection is located on the back of the device under a cover To connect the PoE power supply use the power cable article no A5E49168671 supplied with the SCALANCE PSR9230PoE power supply unit To connect two SCALANCE PSR9230PoE connect the two supplied power cables see section Power cables for SCALANCE XR326 2C PoE WG Close the c...

Страница 61: ... You needed the following tools Torx screwdriver size T10 Slotted screwdriver blade width 3 5 mm Connecting up To connect the PoE power supply proceed as follows 1 Loosen the screws of the cover with a Torx screwdriver 2 Remove the cover 3 Insert and screw the plug with a slotted screwdriver torque 0 5 Nm 0 6 Nm Disconnecting To disconnect the PoE power supply proceed as follows 1 Switch off the P...

Страница 62: ...ANCE PSR9230PoE PoE power supply in the corresponding operating instructions see the section Introduction Page 5 Additional documentation Connecting up 6 6 PoE power supply power expansion SCALANCE XR 300WG 62 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 63: ... as an accessory Position and assignment 6 6 5 4 3 2 1 2162 1 6 7 8 9 2 3 4 5 Figure 6 6 Position and pin assignment of the serial interface RJ 11 socket on the SCALANCE XR 300WG and pin assignment of the D sub socket Assignment of the connecting cable The connecting cable listed in the Accessories section has the following pin assignment Contact Pin assignment of the RJ 11 plug Pin assignment of ...

Страница 64: ... jack on the device The RJ 11 jack on the device has a pinout to match the RJ 11 plug of the connecting cable mentioned above Connecting up 6 7 Serial interface SCALANCE XR 300WG 64 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 65: ...owest leakage resistance to ground in the vicinity of the power feed in With automation components functional ground also ensures interference free operation of a controller Via the functional ground interference currents coupled in via the connecting cables are discharged to ground Connect functional grounding via a grounding screw The functional ground must be implemented with low impedance The ...

Страница 66: ...Loosen the grounding screw 2 Put the grounding terminal and the grounding screw together as shown in the drawing 3 Tighten the grounding screw with a maximum tightening torque of 1 5 Nm Connecting up 6 8 Functional ground SCALANCE XR 300WG 66 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 67: ...s and property from too high contact voltages Connect protective grounding via a grounding bolt WARNING Connect the second protective conductor Due to the possible leakage currents it is imperative that you connect a second protective conductor permanently to the device The work must be performed by a specialist according to IEC 62368 1 To wire a permanently connected protective grounding use copp...

Страница 68: ...eed as follows 1 Put the parts and together on the grounding bolt as shown in the drawing 2 Tighten the nut with a maximum tightening torque of 1 5 Nm Connecting up 6 9 Protective grounding PoE variants SCALANCE XR 300WG 68 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 69: ...ile holding down the button 3 Hold down the button until the red fault LED F starts to flash 4 Release the button as long as the red error LED is still flashing This time only lasts a few seconds The bootloader of the device waits in this status for a new firmware file that you can download by TFTP 5 Connect a PC to an Ethernet port of the device with an Ethernet cable 6 Assign an IP address to th...

Страница 70: ... on completion of the startup phase To reset the device to the factory defaults during the startup phase follow the steps below 1 Turn off the power to the device 2 Now press the RESET button and reconnect the power supply to the device while holding down the button 3 Hold down the button until the red error LED F stops flashing and is permanently lit 4 Now release the button and wait until the fa...

Страница 71: ... voltage 24 VDC Voltage range 19 2 to 28 8 VDC Safe Extra Low Voltage SELV Cable cross section 0 75 mm2 20 AWG Property Implemented redundantly Fusing 5 A at least 60 V Or power supply with LPS or NEC class 2 Current consumption 300 mA Effective power loss 7 2 W Permitted ambient conditions Ambient temperature During operation up to 3000 m above mean sea level 0 to 60 During storage 40 C to 85 C D...

Страница 72: ...rack mounting DIN rail Wall mounting Mean time between failure MTBF MTBF EN IEC 61709 40 C 56 years Technical specifications 8 1 Technical specifications of the SCALANCE XR324WG SCALANCE XR 300WG 72 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 73: ...nted redundantly Current consumption At 100 VAC 200 mA At 240 V AC 100 mA Effective power loss 9 W Permitted ambient conditions Ambient temperature During operation up to 3000 m above mean sea level 0 to 60 During storage 40 C to 85 C During transportation 40 C to 85 C Relative humidity During operation at 25 95 without condensation Housing dimensions and weight Design Rack Housing material Metal ...

Страница 74: ...Socket 3 pin Rated voltage 100 to 240 V AC Voltage range 85 to 264 VAC Frequency 50 Hz to 60 Hz Frequency range 47 Hz to 63 Hz Properties Not implemented redundantly Current consumption At 100 VAC Max 4 A At 240 V AC Effective power loss Max 280 W Depending on the effective power loss of the con nected PoE consumers Permitted ambient conditions Ambient temperature During operation up to 3000 m abo...

Страница 75: ...s 19 rack mounting DIN rail Wall mounting Mean time between failure MTBF MTBF EN IEC 61709 40 C 25 years Technical specifications 8 2 Technical specifications of SCALANCE XR326 2C PoE WG SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 75 ...

Страница 76: ...s interface Serial interface Quantity 1 Connector RJ 11 jack Electrical data Power supply Design Terminal block 2 terminals Rated voltage 24 VDC Voltage range 19 2 to 28 8 VDC Safe Extra Low Voltage SELV Cable cross section 0 75 mm2 20 AWG Property Implemented redundantly Fusing 5 A at least 60 V Or power supply with LPS or NEC class 2 Current consumption 500 mA Effective power loss 12 W Permitted...

Страница 77: ...g DIN rail Wall mounting Mean time between failure MTBF MTBF EN IEC 61709 40 C 43 years 1 Depending on which pluggable transceiver you use the maximum ambient temperature can change see section Accessories Page 24 Technical specifications 8 3 Technical specifications of the SCALANCE XR328 4C WG SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 77 ...

Страница 78: ...ck Electrical data Power supply Design Socket 3 pin Rated voltage 100 to 240 V AC Voltage range 85 to 264 VAC Frequency 50 Hz to 60 Hz Frequency range 47 Hz to 63 Hz Properties Not implemented redundantly Current consumption At 100 VAC 300 mA At 240 V AC 150 mA Effective power loss 15 W Permitted ambient conditions Ambient temperature 1 During operation up to 3000 m above mean sea level 0 to 60 Du...

Страница 79: ...BF MTBF EN IEC 61709 40 C 39 years 1 Depending on which pluggable transceiver you use the maximum ambient temperature can change see section Accessories Page 24 Technical specifications 8 3 Technical specifications of the SCALANCE XR328 4C WG SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 79 ...

Страница 80: ...tics interface Serial interface Quantity 1 Connector RJ 11 jack Electrical data Power supply Design Terminal block 2 terminals Rated voltage 24 VDC Voltage range 19 2 to 28 8 VDC Safe Extra Low Voltage SELV Cable cross section 0 75 mm2 20 AWG Property Implemented redundantly Fusing 5 A at least 60 V Or power supply with LPS or NEC class 2 Current consumption 900 mA Effective power loss 21 6 W Perm...

Страница 81: ... DIN rail Wall mounting Mean time between failure MTBF MTBF EN IEC 61709 40 C 33 years 1 Depending on which pluggable transceiver you use the maximum ambient temperature can change see section Accessories Page 24 Technical specifications 8 4 Technical specifications of the SCALANCE XR328 4C WG GE SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 81 ...

Страница 82: ... jack Electrical data Power supply Design Socket 3 pin Rated voltage 100 to 240 V AC Voltage range 85 to 264 VAC Frequency 50 Hz to 60 Hz Frequency range 47 Hz to 63 Hz Properties Not implemented redundantly Current consumption At 100 VAC 400 mA At 240 V AC 200 mA Effective power loss 27 W Permitted ambient conditions Ambient temperature During operation up to 3000 m above mean sea level 0 to 60 D...

Страница 83: ...k mounting DIN rail Wall mounting Mean time between failure MTBF MTBF EN IEC 61709 40 C 31 years Technical specifications 8 4 Technical specifications of the SCALANCE XR328 4C WG GE SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 83 ...

Страница 84: ...ALANCE XR 300WG IEC 60068 2 27 shock IEC 60068 2 6 vibration 15 g 11 ms duration 6 shocks per axis 10 58 Hz 0 075 mm 85 150 Hz 1 g 1 octave min 20 sweeps Technical specifications 8 5 Mechanical stability in operation SCALANCE XR 300WG 84 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 85: ...55 m IE FC TP Marine Trailing Flexible cable with IE FC Outlet RJ 45 10 m TP cord 0 to 75 m 10 m TP cord IE FC TP Marine Trailing Flexible cable with IE FC RJ 45 Plug 180 0 to 85 m IE FC TP standard cable with IE FC Outlet RJ 45 10 m TP cord 0 to 90 m 10 m TP cord IE FC TP standard cable with IE FC RJ 45 Plug 180 0 to 100 m Technical specifications 8 6 Cable lengths SCALANCE XR 300WG Operating Ins...

Страница 86: ...931 128 84459 844595 8023670 256 45290 452899 4415773 512 23496 234962 2320257 1024 11973 119732 1189835 1280 9615 96154 955529 1518 8127 81274 807664 Note The number of SCALANCE XR 300WG modules connected in a line influences the frame delay When a frame passes through IE switches of the SCALANCE XR 300WG product line it is delayed by the store and forward function of the device with a 64 byte fr...

Страница 87: ... XR 300WG Figure 9 1 Width and height based on the example of a 24 V DC variant SCALANCE XR 300WG 24 VDC variant view from above Figure 9 2 Depth SCALANCE XR 300WG 240 VAC variant view from above Figure 9 3 Depth SCALANCE XR 300WG Operating Instructions 03 2021 C79000 G8976 C454 07 87 ...

Страница 88: ...SCALANCE XR 300WG PoE variant view from above Figure 9 4 Depth Dimension drawings SCALANCE XR 300WG 88 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 89: ...upport industry siemens com cs ww en ps 15273 cert Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive There is therefore no declaration of conformity relating to the EC Machinery Directive 2006 42 EC for these devices If the devices are part of the equipment of a machine they must be included into the EU declaration of conformity procedu...

Страница 90: ...57 374 Note Only variants with 240 V AC power supply meet the requirements of this approval 2014 30 EU EMC EMC directive of the European Parliament and of the Council of February 26 2014 on the approximation of the laws of the member states relating to electromagnetic compatibility official journal of the EU L96 29 03 2014 p 79 106 2011 65 EU RoHS Directive of the European Parliament and of the Co...

Страница 91: ...VD SIMATIC NET Manual Collection On the Internet pages of Siemens Industry Online Support https support industry siemens com cs ww en view 78381013 The SIMATIC NET products described in these operating instructions meet the requirements of the EU directive 2014 34 EU Equipment and Protective Devices for Use in Potentially Explosive Atmospheres Note Type of protection of the device The devices are ...

Страница 92: ...spheres Part 0 Equipment General requirements ec ATEX classification II 3 G Ex ec IIC T4 Gc Certificate no DEKRA 18ATEX0025 X The products meet the requirements of the following standards EN 60079 7 Explosive atmospheres Part 7 Equipment protection through increased safety e EN 60079 0 Explosive atmospheres Part 0 Equipment General requirements You will find the current versions of the standards i...

Страница 93: ... requirements of the following standards IEC 60079 7 Explosive atmospheres Part 7 Equipment protection through increased safety e IEC 60079 0 Explosive atmospheres Part 0 Equipment General requirements You will find the current versions of the standards in the currently valid IECEx certificates Note Only variants with 24 VDC power supply meet the requirements of this approval Note for devices with...

Страница 94: ...nments EN 61000 6 4 Electromagnetic compatibility EMC Part 6 4 Generic standards Emission standard for industrial environments You will find the current versions of the standards in the currently valid EC declaration of conformity RoHS The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011 65 EC for the restriction of the use of certain ha...

Страница 95: ...unication technology CSA C22 2 No 62368 1 information communication technology Report no E115352 cULus Approval Hazardous Location cULus Listed I T E FOR HAZ LOC Underwriters Laboratories Inc complying with UL 60950 1 Information Technology Equipment ANSI ISA 12 12 01 2007 CSA C22 2 No 213 M1987 Approved for use in Cl 1 Div 2 GP A B C D T4 Cl 1 Zone 2 GP IIC T4 Report no E240480 Note Only variants...

Страница 96: ...ng for the customs union EAC Eurasian Conformity Eurasian Economic Union of Russia Belarus Armenia Kazakhstan and Kyrgyzstan Declaration of conformity according to the technical regulations of the customs union TR ZU FDA and IEC marking The following devices meet the FDA and IEC requirements listed below Device CLASS 1 LASER Product SCALANCE XR324WG SCALANCE XR328 4C WG In modular devices you can ...

Страница 97: ...pport industry siemens com cs ww en view 60612658 WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility Only use expansions that are approved for the system Note The test was performed with a device and a con...

Страница 98: ...Approvals SCALANCE XR 300WG 98 Operating Instructions 03 2021 C79000 G8976 C454 07 ...

Страница 99: ...2 F Factory defaults 29 70 Factory setting 29 70 Fault LED 21 22 23 27 Functional ground 65 G Glossary 7 Grounding screw 21 22 23 66 H Housing 71 73 74 76 78 80 82 I Installation 71 73 74 76 78 80 82 Installation on a DIN rail 42 L LED display Fault LED 21 22 23 27 LED L 21 22 23 Port LED 21 22 23 27 28 RM LED 21 22 23 27 LED L 21 22 23 M MDI MDI X autocrossover 52 Mounting Bracket 21 22 23 40 Rac...

Страница 100: ...eset device 29 70 Reset to Factory Defaults 29 70 RM LED 21 22 23 27 S Safety notices for installation 35 general 9 Use in hazardous areas 9 35 49 when connecting up 49 Sealing plug 46 47 SELECT SET button 69 Serial interface 21 22 23 Connecting cable 24 63 SFP transceiver 5 25 SFP transceiver 26 SIMATIC NET glossary 7 SIMATIC NET manual 7 Slot 46 Startup phase 29 70 System manual 6 38 97 W Wall m...