SCALANCE XP-200
Operating Instructions, 05/2016, C79000-G8976-C428-01
67
Upkeep and maintenance
5
5.1
Downloading new firmware using TFTP without WBM and CLI
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens
can be downloaded to the device.
Pressing the "RESET" button
To load new firmware, you require the "RESET" button. When pressing the button,
remember the information in the section "RESET button (Page 33)".
Procedure with Microsoft Windows
Using TFTP, you can supply a device with new firmware even when it cannot be reached
using WBM or CLI. This section explains the procedure based on the example of Microsoft
Windows.
Follow the steps below to load new firmware using TFTP:
1.
Turn off the power to the device.
2.
Press the button and reconnect the power supply to the device while holding down the
button.
3.
Hold down the button until the red fault LED "F" starts to flash.
4.
Release the button as long as the red error LED is still flashing..
Note
This time only lasts a few seconds.
The bootloader of the device waits in this status for a new firmware file that you can
download by TFTP.
5.
Connect a PC to port 0.1 via an Ethernet cable.
6.
Assign an IP address to the device using DHCP or the Primary Setup Tool.
Содержание SCALANCE XP-200
Страница 8: ...Introduction SCALANCE XP 200 8 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Страница 50: ...Installation 3 5 Rack mounting SCALANCE XP 200 50 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Страница 66: ...Connecting up 4 7 Functional ground SCALANCE XP 200 66 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Страница 84: ...Dimension drawings SCALANCE XP 200 84 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Страница 92: ...Approvals SCALANCE XP 200 92 Operating Instructions 05 2016 C79000 G8976 C428 01 ...