Connecting up
4.2 Industrial Ethernet
SCALANCE XP-200
54
Operating Instructions, 05/2016, C79000-G8976-C428-01
Gigabit Ethernet
For connection to Industrial Ethernet at 10/100/1000 Mbps, the device has the following M12
interfaces: X-coded, 8-pin, female.
Pin number
Assignment
1
D0+
2
D0-
3
D1+
4
D1-
5
D3+
6
D3-
7
D2-
8
D2+
Connecting an Ethernet port
1.
Connect the plug and socket. Make sure that they lock in place correctly.
2.
Tighten the knurled screw (torque 1 Nm).
To allow an orderly cable outlet, you can arrange the angled M12 plug as follows:
Содержание SCALANCE XP-200
Страница 8: ...Introduction SCALANCE XP 200 8 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Страница 50: ...Installation 3 5 Rack mounting SCALANCE XP 200 50 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Страница 66: ...Connecting up 4 7 Functional ground SCALANCE XP 200 66 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Страница 84: ...Dimension drawings SCALANCE XP 200 84 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Страница 92: ...Approvals SCALANCE XP 200 92 Operating Instructions 05 2016 C79000 G8976 C428 01 ...