Description of the device
2.6 C-PLUG
SCALANCE XP-200
Operating Instructions, 05/2016, C79000-G8976-C428-01
39
The C-PLUG slot is on the top of the device housing under a cover.
Replacing a C-PLUG.
Removing a C-PLUG
1.
Turn off the power to the device.
2.
Loosen the screws of the cover.
3.
Remove the cover.
4.
Insert a screwdriver between the front edge of the C-PLUG (A) and the slot and release
the C-PLUG.
5.
Remove the C-PLUG.
6.
Close the cover (tightening torque =.8 Nm), to ensure that the device is closed and water
and dust proof.