Signaling contact 100 to 240 VAC / 60 to 250 VDC
The signaling contact is connected to a 3-pin plug-in terminal block.
Table 6-2
Pin assignment of the 100 to 240 VAC / 60 to 250 VDC signaling contact
Pin number
Assignment
F1
F2
F3
F1
NC contact
F2
Root
F3
NO contact
To wire up the signaling contact, use a copper cable of category 18-8 AWG or cable with a
cross-section of 0.75 to 6 mm².
NOTICE
Securing cables with dangerous voltage
Make sure that the connector cannot be released accidentally by pulling on the connecting
cable. Lay the cables in cable ducts or cable channels and secure the cables, where
necessary, with cable ties.
NOTICE
Securing cables with dangerous voltage
Make sure that the connector cannot be released accidentally by pulling on the connecting
cable. Lay the cables in cable ducts or cable channels and secure the cables, where
necessary, with cable ties.
Connecting
6.6 Signaling contact
SCALANCE X-300EEC
Compact Operating Instructions, 11/2019, A5E02630809-14
47