● "FPGA File"
Name and directory path of the file from which you want to load the new FPGA configuration.
● "SSL Private Key File"
Name and directory path of the file from which you want to load the new SSL key.
● "SSL Certificate File"
Name and directory path of the file from which you want to load the new SSL certificate.
How to download data using HTTP
1. In the relevant text box, enter a name and directory path for the file from which you want
to take the data.
2. Start the download of the relevant file by clicking one of the buttons "Load Configuration
and Restart", "Load Firmware and Restart" or "Load FPGA File and Restart", "Load Private
Key" or "Load Certificate and Restart". Following the download, there is an automatic restart
except with "Load Private Key" and the device starts up with the new data. Please note the
following:
Note
If a firmware version is loaded that is older than the current version, it is possible that the
current parameter record cannot be adopted. In this case the current IP address is deleted
and access using WBM, CLI or SNMP is no longer possible. This means that after
downloading the firmware and restarting the device, the IP address needs to be assigned
again with the Primary Setup Tool and the required parameters set again.
Note
If newer firmware and a newer FPGA version required on the device, it is advisable to
download the FPGA and then the firmware following the restart.
How to save data using HTTP
1. Start the save function by clicking either the "Save Configuration" or "Save Private MIB"
button.
2. You will be prompted to select a storage location and a name for the file or to accept the
proposed file name.
Reusing configuration data
Saving and reading in configuration data reduces the effort if several devices of the
SCALANCE X-200RNA product line have the same configuration and when IP addresses are
obtained using DHCP.
Save the configuration data on your computer after you have configured a SCALANCE
X-200RNA.
Download this file to all other devices of the SCALANCE X-200RNA product line you want to
configure.
If individual settings are necessary for specific devices, these must be made online.
Functional description and configuration using Web Based Management
7.7 The "System" menu
SCALANCE X-200RNA
Operating Instructions, 10/2016, C79000-G8976-C342-04
87
Содержание SCALANCE X-200RNA
Страница 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 12: ...Introduction SCALANCE X 200RNA 12 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 16: ...Safety notices SCALANCE X 200RNA 16 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 54: ...Descriptions of the products 4 8 LEDs SCALANCE X 200RNA 54 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 62: ...Installation 5 3 Wall mounting SCALANCE X 200RNA 62 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 70: ...Connecting up 6 4 Grounding SCALANCE X 200RNA 70 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 142: ...Approvals and marking SCALANCE X 200RNA 142 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 146: ...Technical specifications SCALANCE X 200RNA 146 Operating Instructions 10 2016 C79000 G8976 C342 04 ...