Installation
5
5.1
Types of installation
The SCALANCE X-200RNA devices can be mounted in the following ways:
● Installing on a 35 mm DIN rail
● Wall mounting
Note
Installation on a SIMATIC S7-300 standard rail is not possible
Note
When installing and operating the device, keep to the installation instructions and safety-
related notices in this description and in the SIMATIC NET Industrial Ethernet network manual.
Unless stated otherwise, the mounting options listed below apply to all devices of the type
SCALANCE X-200RNA.
Note
Provide suitable shade to protect SCALANCE X-200RNA devices against direct sunlight. This
avoids unwanted warming of devices of the type SCALANCE X‑200RNA and prevents
premature aging of the device and cabling.
WARNING
Location for mounting a SCALANCE X204RNA EEC
If a SCALANCE X204RNA EEC is operated at ambient temperatures between 60 °C and 70
°C, the housing temperature may exceed 70 °C.
When installing the X204RNA EEC, select a location where only qualified service personnel
or trained users have access to it.
Operation of the SCALANCE X204RNA EEC at ambient temperatures of 60 °C - 70 °C is
only permitted under these conditions.
WARNING
Ambient temperatures
If temperatures in excess of 70 °C occur on cables or at cable feed-in points, or the
temperature at the branching point of the cables exceeds 80 °C, special measures need to
be taken. If the equipment is operated at an ambient temperature of 50 °C - 60 °C, use cables
with a permitted ambient temperature of at least 80 °C.
SCALANCE X-200RNA
Operating Instructions, 10/2016, C79000-G8976-C342-04
55
Содержание SCALANCE X-200RNA
Страница 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 12: ...Introduction SCALANCE X 200RNA 12 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 16: ...Safety notices SCALANCE X 200RNA 16 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 54: ...Descriptions of the products 4 8 LEDs SCALANCE X 200RNA 54 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 62: ...Installation 5 3 Wall mounting SCALANCE X 200RNA 62 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 70: ...Connecting up 6 4 Grounding SCALANCE X 200RNA 70 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 142: ...Approvals and marking SCALANCE X 200RNA 142 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 146: ...Technical specifications SCALANCE X 200RNA 146 Operating Instructions 10 2016 C79000 G8976 C342 04 ...