![Siemens SCALANCE X-200RNA Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/siemens/scalance-x-200rna/scalance-x-200rna_operating-instructions-manual_383816052.webp)
The status of the power supply is indicated by a green LED:
Device type SCALANCE
LED lit green
LED lit yellow
LED not lit
X204RNA (HSR)
1
2
3
X204RNA EEC (HSR)
4
-
5
X204RNA EEC (PRP/HSR)
If configured as HSR device.
4
-
5
1. Both L power supplies are connected
(redundant supply).
2. One L power supply is connected
(non-redundant supply).
3. Power supply L1 and L2 are not connected or supply voltages are <14 V.
4. Power supply L is connected
5. Power supply L is not connected or the supply voltage is too low.
4.8.2.3
Port LED
The LEDs signal the following port statuses of the SCALANCE X-200RNA (HSR).
The status of the ports is indicated by two-color LEDs:
Device type SCALANCE
LED lit green
LED lit yellow
LED flashes yel‐
low
Number of LEDs
X204RNA (HSR)
2 port LEDs
1
2, 3
4
2 PRP port LEDs
1
2, 3
4
X204RNA EEC (HSR)
2 port LEDs
1
2, 3
4
2 PRP port LEDs
1
2, 3
4
X204RNA EEC (PRP/HSR)
If configured as HSR device.
2 port LEDs
1
2, 3
4
2 PRP port LEDs
1
2, 3
4
1. TP link exists, no data reception.
2. TP link, data received at TP port.
3. Device startup, the LED is lit for approx. 6 seconds.
4. Setting or display of the fault mask.
4.8.2.4
LED displays during startup
When the SCALANCE X-200RNA (HSR) starts up, the following LED displays light up in the
order shown:
1. Power LEDs (green) light up immediately after turning on the power.
2. Port LEDs go off, the red error LED is lit for approx. 10 seconds.
Descriptions of the products
4.8 LEDs
SCALANCE X-200RNA
52
Operating Instructions, 10/2016, C79000-G8976-C342-04
Содержание SCALANCE X-200RNA
Страница 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 12: ...Introduction SCALANCE X 200RNA 12 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 16: ...Safety notices SCALANCE X 200RNA 16 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 54: ...Descriptions of the products 4 8 LEDs SCALANCE X 200RNA 54 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 62: ...Installation 5 3 Wall mounting SCALANCE X 200RNA 62 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 70: ...Connecting up 6 4 Grounding SCALANCE X 200RNA 70 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 142: ...Approvals and marking SCALANCE X 200RNA 142 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Страница 146: ...Technical specifications SCALANCE X 200RNA 146 Operating Instructions 10 2016 C79000 G8976 C342 04 ...