5.4 Digital input/output
SCALANCE M804PB
Operating Instructions, 07/2018, C79000-G8976-C496-01
43
5.4
Digital input/output
The digital input/output (relay contact) is a floating switch with which error/fault states can be
signaled by breaking the contact.
CAUTION
Damage due to voltage being too high or too low
The voltage at the digital input/output must not exceed 30 VDC and not fall below -30 VDC,
otherwise the digital input/output will be destroyed.
Note
Interference pulse
Zo avoid evaluating an interference pulse, the pulse for the signal 1 (TRUE / HIGH) must be
at least 200 ms.
Rules for user wiring
●
Always wire the digital input/output in pairs-
●
The maximum permitted cable length is 30 m.